Report No.: BL-SZ1680250-601
12 / 129
4 GENERAL TEST CONFIGURATIONS
4.1 Test Environments
During the measurement, the normal environmental conditions were within the listed ranges:
Relative Humidity
45% - 55%
Atmospheric Pressure
100 kPa - 102 kPa
Temperature
NT (Normal Temperature)
+22
℃
to +25
℃
Working Voltage of the EUT
NV (Normal Voltage)
12 V
4.2 Test Equipment List
Description
Manufacturer
Model
Serial No.
Cal. Date
Cal. Due
Spectrum Analyzer
ROHDE&SCHWARZ
FSV-30
103118
2016.07.13
2017.07.12
Vector Signal
Generator
ROHDE&SCHWARZ SMBV100A
177746
2016.07.13
2017.07.12
Signal Generator
ROHDE&SCHWARZ SMB100A
260592
2016.07.13
2017.07.12
Switch Unit with OSP-
B157
ROHDE&SCHWARZ
OSP120
101270
2016.07.13
2017.07.12
Spectrum Analyzer
AGILENT
E4440A
MY45304434 2015.10.15
2016.10.14
EMI Receiver
ROHDE&SCHWARZ
ESRP
101036
2016.07.05
2017.07.04
LISN
SCHWARZBECK
NSLK 8127
8127-687
2016.07.05
2017.07.04
Bluetooth Tester
ROHDE&SCHWARZ
CBT
101005
2016.07.13
2017.07.12
Power Splitter
KMW
DCPD-LDC 1305003215
--
--
Power Sensor
ROHDE&SCHWARZ
NRP-Z21
103971
2016.07.13
2017.07.12
Attenuator (20 dB)
KMW
ZA-S1-201
110617091
--
--
Attenuator (6 dB)
KMW
ZA-S1-61
1305003189
--
--
DC Power Supply
ROHDE&SCHWARZ HMP2020
018141664
2016.07.13
2017.07.12
Temperature Chamber
ANGELANTIONI
SCIENCE
NTH64-40A
1310
2016.07.13
2017.07.12
Test Antenna-
Loop(9 kHz-30 MHz)
SCHWARZBECK
FMZB 1519
1519-037
2015.07.22
2017.07.21
Test Antenna-
Bi-Log(30 MHz-3 GHz)
SCHWARZBECK
VULB 9163
9163-624
2015.07.22
2017.07.21
Test Antenna-
Horn(1-18 GHz)
SCHWARZBECK
BBHA
9120D
9120D-1148
2015.07.22
2017.07.21
Test Antenna-
Horn(15-26.5 GHz)
SCHWARZBECK
BBHA 9170
9170-305
2015.07.22
2017.07.21
Anechoic Chamber
RAINFORD
9m*6m*6m
N/A
2015.02.28
2017.02.27
ChangNing
CN-130701
130703
--
--