Report No.: BL-SZ1680250-601
13 / 129
4.3
Measurement Uncertainty
The following measurement uncertainty levels have been estimated for tests performed on the EUT
as specified in CISPR 16-4-2.
This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.
Measurement
Value
Occupied Channel Bandwidth
±4%
RF output power, conducted
±1 .4 dB
Power Spectral Density, conducted
±2.5 dB
Unwanted Emissions, conducted
±2.8 dB
All emissions, radiated
±5.4 dB
Temperature
±1°C
Humidity
±4%
4.4 Description of Test Setup
4.4.1 For Antenna Port Test
(Diagram 1)