background image

9 / 54

0006080404_201104

WARNING NOTES FOR THE USER 

HOW TO USE THE BURNER SAFELY

FOREWORD 

These warning notes are aimed at ensuring the safe use of the components of heating systems for civil use and the production of hot water. 

They indicate how to act to avoid the essential safety of the components being compromised by incorrect or erroneous installation and by 

improper or unreasonable use. The warning notes provided in this guide also seek to make the consumer more aware of safety problems in 

general, using necessarily technical but easily understood language. The manufacturer is not liable contractually or extra contractually for any 

damage caused by errors in installation and in use, or where there has been any failure to follow the manufacturer’s instructions.

GENERAL WARNING NOTES 

•  The instruction booklet is an integral and essential part of the product and must be given to the user. Carefully read the warnings in the 

booklet as they contain important information regarding safe installation, use and maintenance. Keep the booklet to hand for consultation 

when needed. 

•  Equipment must be installed in accordance with current regulations, with the manufacturer’s instructions and by qualified technicians. By 

the term ‘qualified technicians’ is meant persons that are competent in the field of heating components for civil use and for the production 

of hot water and, in particular, assistance centres authorised by the manufacturer. Incorrect installation may cause damage or injury to 

persons, animals or things. The manufacturer will not in such cases be liable. 

•  After removing all the packaging make sure the contents are complete and intact. If in doubt do not use the equipment and return it to the 

supplier. The packaging materials (wooden crates, nails, staples, plastic bags, expanded polystyrene, etc.) must not be left within reach of 

children as they may be dangerous to them. They should also be collected and disposed on in suitably prepared places so that they do no 

pollute the environment. 

•  Before carrying out any cleaning or maintenance, switch off the equipment at the mains supply, using the system’s switch or shut-off systems. 
•  If there is any fault or if the equipment is not working properly, de-activate the equipment and do not attempt to repair it or tamper with 

it directly. In such case get in touch with only qualified technicians. Any product repairs must only be carried out by BALTUR authorised 

assistance centres using only original spare parts. Failure to act as above may jeopardise the safety of the equipment. To ensure the effi

-

ciency and correct working of the equipment, it is essential to have periodic maintenance carried out by qualified technicians following the 

manufacturer’s instructions. 

•  If the equipment is sold or transferred to another owner or if the owner moves and leaves the equipment, make sure that the booklet always 

goes with the equipment so it can be consulted by the new owner and/or installer.

•  For all equipment with optionals or kits (including electrical), only original accessories must be used. 

BURNERS 

•  This equipment must be used only for its expressly stated use: applied to boilers, hot air boilers, ovens or other similar equipment and not 

exposed to atmospheric agents. Any other use must be regarded as improper use and hence dangerous. 

•  The burner must be installed in a suitable room that has ventilation in accordance with current regulations and in any case sufficient to 

ensure correct combustion 

•  Do not obstruct or reduce the size of the burner’ air intake grills or the ventilation openings for the room where a burner or a boiler is installed 

or dangerous mixtures of toxic and explosive gases may form. 

•  Before connecting the burner check that the details on the plate correspond to those of the utility supplies (electricity, gas, light oil or other fuel). 
•  Do not touch hot parts of the burner. These, normally in the areas near to the flame and any fuel pre-heating system, become hot when the 

equipment is working and stay hot for some time after the burner has stopped. 

•  If it is decided not to use the burner any more, the following actions must be performed by qualified technicians:
  a) Switch off the electrical supply by disconnecting the power cable from the master switch. 
  b) Cut off the fuel supply using the shut-off valve and remove the control wheels from their position.
  c) Render harmless any potentially dangerous parts.

Special warning notes 

•  Check that the person who carried out the installation of the burner fixed it securely to the heat generator so that the flame is generated 

inside the combustion chamber of the generator itself. 

•  Before starting up the burner, and at least once a year, have qualified technicians perform the following operations: 

a) Set the burner fuel capacity to the power required by the heat generator.
b) Adjust the combustion air flow to obtain combustion yield of at least the minimum set by current regulations.
c) Carry out a check on combustion to ensure the production of noxious or polluting unburnt gases does not exceed limits permitted by 

current regulations. 

d) Check the adjustment and safety devices are working properly. 
e) Check the efficiency of the combustion products exhaust duct. 
f) Check at the end of the adjustments that all the adjustment devices mechanical securing systems are properly tightened. 
g) Make sure that the use and maintenance manual for the burner is in the boiler room.

•  If the burner repeatedly stops in lock-out, do not keep trying to manually reset but call a qualified technicians to sort out the problem.
•  The running and maintenance of the equipment must only be carried out by qualified technicians, in compliance with current regulations.

Summary of Contents for Spark 18 DSGW

Page 1: ...18 DSGW SPARK 26 DSG DSGW SPARK 35 DSG DSGW Notice d instructions Manual de instrucciones ISTRUZIONI ORIGINALI IT ORIGINAL INSTRUCTIONS ARE IT INSTRUCCIONES ORIGINALES IT ISTRUCTIONS ORIGINALES IT 00...

Page 2: ......

Page 3: ...rous accidents SP Antes de empezar a usar el quemador lea detenidamente el folleto ADVERTENCIAS DIRIGIDAS AL USUARIO PARA USAR CON SEGURIDAD EL QUEMADOR que va con el manual de instruc ciones y que co...

Page 4: ...lato gasolio Tali prodotti sono pertanto marcati 0085 04 01 2010 Dr Riccardo Fava Amministratore Delegato CEO Baltur S p A BALTUR S p A Via Ferrarese 10 44042 CENTO Ferrara ITALIA Tel 051 684 37 11 F...

Page 5: ...combinaci n lado di sel Estos productos est n marcados con 0085 Dr Riccardo Fava Director Gerente Director General BALTUR S p A Via Ferrarese 10 44042 CENTO Ferrara ITALIA Tel 051 684 37 11 Fax 051 6...

Page 6: ...ram 47 Pump particuler 48 Electrodes adjustment Air regulation principle 50 Adjustment diagram for servomotor 51 Electric diagram 52 FRAN AIS PAGE 33 Caracteristiques techniques 15 Connexion hydrauliq...

Page 7: ...e si dovesse traslocare e lasciare l apparecchio assicurarsi sempre che il libretto accompagni l apparecchio in modo che possa essere consultato dal nuovo proprietario e o dall installatore Per tutti...

Page 8: ...compromettere il buon funzionamento del bruciatore Per la prima messa in funzione dell apparecchio far effettuare da personale professionalmente qualificato le seguenti verifiche a il controllo della...

Page 9: ...equipment is sold or transferred to another owner or if the owner moves and leaves the equipment make sure that the booklet always goes with the equipment so it can be consulted by the new owner and o...

Page 10: ...by qualified technicians and in compliance with current law and regulations since incorrect installation may cause damage to person animals or things for which damage the manufacturer shall not can b...

Page 11: ...ted se muda de casa y deja el aparato hay que asegurarse siempre de que el libro de instrucciones est siempre con el aparato para que pueda ser consultado por el nuevo propietario y o instalador Para...

Page 12: ...n comprometer el buen funcionamiento del quemador La primera vez que se pone en funcionamiento el aparato el personal cualificado profesionalmente tiene que controlar a la estanqueidad en el tramo int...

Page 13: ...appareil doit tre vendu ou transf r un autre propri taire ou si celui ci doit d m nager et laisser ce dernier toujours v rifier que la notice accompagne l appareil afin qu il puisse tre consulter par...

Page 14: ...le bon fonctionnement du br leur Lors de la premi re mise en service de l appareil faire effectuer les v rifications suivantes par du personnel qualifi a le contr le de l tanch it de la partie interne...

Page 15: ...mbustibile gasolio Fuel max viscosity light oil Viscosite maxi combustible gas oil Viscosidad max combustible gasoleo 1 5 E a at 20 C Alimentaz elettrica Electrical feeding Tension Alimentaci n electr...

Page 16: ...13 Bride de fixation br leur 14 Couvercle br leur 15 Electrovanne 16 Vis de r glange de disque t te 1 Light oil pump 2 Control box 3 Reset button 4 Fan motor 5 Manual switch 6 Connectors 7 Ignition t...

Page 17: ...114 170 200 M10 135 SPARK 26 DSG 490 245 245 375 275 100 750 105 300 139 114 170 200 M10 150 SPARK 26 DSGW 450 220 230 355 262 5 92 5 710 105 300 139 114 170 200 M10 150 SPARK 35 DSG 490 245 245 385...

Page 18: ...18 54 0006080404_201104 CAMPO DI LAVORO WORKING FIELD RANGO DE TRABAJO...

Page 19: ...ontrollo manometro e vuotometro Per un funzionamento sicuro e silenzioso la depressione in aspirazione non deve superare i 35 cm Hg pari a 0 46 bar Pressione max aspirazione e ritorno 1 5 bar COLLEGAM...

Page 20: ...ombustibile 6 Tubo di aspirazione 2 Tubazione di alimentazione 7 Tubo di ritorno del bruciatore 3 Filtro a rete 8 Dispositivo automatico intercettazione 4 Bruciatore a bruciatore fermo 5 Degasificator...

Page 21: ...rno del 1 Serbatoio combustibile 6 Tubo di aspirazione 2 Tubazione di alimentazione 7 Tubo di ritorno del bruciatore 3 Filtro a rete 8 Dispositivo automatico intercettazione 4 Bruciatore a bruciatore...

Page 22: ...a fase in cui il dispositivo di comando e controllo si trova nella tabella sottostante sono riepilogate le sequenze dei colori ed il loro significato Per attivare la funzione di diagnosi premere per a...

Page 23: ...alfunzionamento valvole combustibile Malfunzionamento rilevatore fiamma Difettosit nella taratura del bruciatore assenza di combustibile Mancata accensione difettosit trasformatore di accensione 3 lam...

Page 24: ...re l aria allo stretto indispensabile Se l accensione avviene dolcemente disinserire il bruciatore dall interruttore generale ed effettuare un collegamento diretto ponte tra i morsetti del termostato...

Page 25: ...i 2 Fotoresistenza in corto circuito 3 Manca la tensione per interruttore generale aper to o interruttore di massima del contatore scattato o mancanza di tensione in linea 4 La linea dei termostati no...

Page 26: ...ol instruments manometer and vacuumeter To ensure reliable and silent operating conditions the vacuum in suction should not exceed 35 cm Hg equal to 0 46 bar Maximun suction and return pressure 1 5 ba...

Page 27: ...eturn valve DROP TYPE SYSTEM WITH SUPPLY FROM THE TANK TOP 1 Tank 3 Wire net filter 4 Pump 6 Suction pipe 7 Return pipe 8 Automatic fuel interception device at burner shut off 9 One way valve 10 Botto...

Page 28: ...eturn valve DROP TYPE SYSTEM WITH SUPPLY FROM THE TANK TOP 1 Tank 3 Wire net filter 4 Pump 6 Suction pipe 7 Return pipe 8 Automatic fuel interception device at burner shut off 9 One way valve 10 Botto...

Page 29: ...erent operating states are indicated in the form of color codes according to the color code table given below Interface diagnostics is activated by pressing the lockout reset button for at least 3 sec...

Page 30: ...of burner no fuel Faulty ignition equipment 3 blinks Free 4 blinks Extraneous light on burner startup 5 blinks Free 6 blinks Free 7 blinks Too many losses of flame during operation limi tation of the...

Page 31: ...it again to be sure that ignition takes place correctly Open isolating switch to stop the burner and connect the terminals of the thermostat of 2nd flame Now connect the burner again it will staff wi...

Page 32: ...fuel red light on The burner does not start Defective flame with sparks PROBABLE CAUSE 1 Insufficient combustion air 2 Insufficient nozzie since it is dirty or worn out 3 Clogged boiler pipe or chimne...

Page 33: ...ment s r et silencieux la d pression en aspiration ne doit pas d passer 35 cm Hg O 46 bar Pression maxi d aspiration et de retour 1 5 bars CONNEXIONS ELECTRIQUES Les lignes lectriques doivent tre une...

Page 34: ...ximum sur aspiration et retour 1 5 bar Cote P 3 5 m maxi 6 Tuyau d aspiration 7 Tuyau de retour du br leur 8 Dispositif automatique d arr t avec le br leur arr t 9 Soupape unidirectionelle 1 R servoir...

Page 35: ...n maximum sur aspiration et retour 1 5 bar Cote P 3 5 m maxi 6 Tuyau d aspiration 7 Tuyau de retour du br leur 8 Dispositif automatique d arr t avec le br leur arr t 9 Soupape unidirectionelle 1 R ser...

Page 36: ...le diagnostic par interface cf fiche 7614 Si le diagnostic par interface a t activ par erreur se reconna t au faible clignotementrouge de la lampe t moin il peut tre d sactiv par une nouvelle pressio...

Page 37: ...uvais r glage du br leur pas de combustible dispositif d allumage d fectueux clignotement 3 libre clignotement 4 lumi re parasite au d marrage du br leur clignotement 5 libre clignotement 6 libre clig...

Page 38: ...e Si l allumage s effectue en douceur d sactiver le br leur depuis l interrupteur principal et effectuer un branchement direct pont entre les bornes du thermostat de seconde flamme En agissant sur la...

Page 39: ...mpe 4 Manque de gas oil dans la citeme 5 La vanne du tuyau d aspiration est fem e 6 Gicleur obstru 7 Le moteur triphas e toume dans le sens contrair du sens indiqu par la fl che 1 Thermostats chaudi r...

Page 40: ...ntrol man metro y vacu metro Para obtener un funcionamiento silencioso y seguro la depresi n en la aspiraci n no tiene que superar los 4 mm C A lo que es igual a 30 cm Hg Presi n m xima de aspiraci n...

Page 41: ...ALIMENTACI N DESDE LA PARTE SUPERIOR DEL DEP SITO 7 Tubo de retorno del quemador 8 V lvula autom tica de aislamiento con el quemador non funcionante 9 V lvula de retenci n 1 Dep sito de combustible 3...

Page 42: ...CON ALIMENTACI N DESDE LA PARTE SUPERIOR DEL DEP SITO 7 Tubo de retorno del quemador 8 V lvula autom tica de aislamiento con el quemador non funcionante 9 V lvula de retenci n 1 Dep sito de combustibl...

Page 43: ...de los colores y su significado Para activar la funci n de diagn stico hay que pulsar por lo menos durante 3 segundos el bot n de desbloqueo un parpadeo r pido de color rojo indicar que la funci n est...

Page 44: ...las del combustible Mal funcionamiento del detector de llama Defecto en el tarado del quemador ausencia de combustible No se enciende por defecto del transformador de encendido 3 parpadeos Espacio lib...

Page 45: ...i arranca suavemente desconecten el quemador mediante el interruptor general y conecten directamente puente los bornes del termostatos de segunda llama Con la leva a tal efecto ajusten el aire de comb...

Page 46: ...mbustible sin que se encienda la llama testigo rojo encendido El equipo se bloquea sin pulverizar combustible lampada rossa accesa El quemador no arranca Llama defectuosa con presencia de chispas CAUS...

Page 47: ...FLAME NOZZLE 4 1st FLAME NOZZLE 5 VALVE 1st FLAME NORMALLY CLOSED 6 PUMP 12 BAR 7 VALVE 2nd FLAME NORMALLY CLOSED 1 CLAPET DE PIED 2 SERVOMOTEUR DE R GULATION AIR 3 GLICEUR 2eme TAGE 4 GLICEUR 1ere TA...

Page 48: ...FOULEMENT 7 CONNEXION DU VACUOM TRE 1 8 1 ELECTROVALVULA NORMALMENTE ABIERTA 2 CONEXI N PARA MANOMETRO Y PURGA DE AIRE 1 8 3 TORNILLO REGULACI N PRESI N 12 BAR 4 RETORNO 5 ASPIRACION 6 IDA 7 CONEXION...

Page 49: ...9 31 9 61 9 91 10 20 10 48 10 75 11 01 2 00 2 25 7 15 7 65 8 15 8 55 8 97 9 37 9 75 10 12 10 47 10 85 11 15 11 47 11 79 12 09 12 39 2 25 2 50 7 95 8 50 9 01 9 50 9 97 10 41 10 83 11 24 11 64 12 02 12...

Page 50: ...CTRODO N 0002932093N1 Rev 30 11 2004 N 0002932093N2 Rev 30 11 2004 B vite di regolazione disco testa avvitare per aprire il passaggio aria tra disco e testa svitare per chiudere head disk adjustment s...

Page 51: ...HEMA ELECTRIQUE 2 VIS DE REGLAGE 3 CAME REGLAGE AIR 1ere FLAMME 4 CAME INSERTION SOUPAPE 2eme FLAMME ELLE DOIT ETRE REGLEE ENTRE LACAME DE 1ere FLAMME ET LACELLE DE 2eme FLAMME 5 CAME DU VOLET D AIR F...

Page 52: ...52 54 0006080404_201104...

Page 53: ...53 54 0006080404_201104...

Page 54: ...ion without notice El presente cat logo tiene car cter puramente indicativo La Casa por lo tanto se reserva cualquier posibilitad de modificati n de datos t cnicos y otras anotaciones Ce manuel rev t...

Reviews: