![background image](http://html1.mh-extra.com/html/baltur/btl-14p/btl-14p_instruction-manual_4041451031.webp)
E
N
G
L
I
S
H
11 / 18
0006080890_201401
RECOMMENDED NOZZLES
Delavan type B 60° (14P)
MONARCH type R 60° (14P)
Delavan type W 60° (20P- 26P)
NOTE:
The values indicated in the table are purely
indicative; for best burner performance
adjustment needs to be made in accordance
with the demands of the particular boiler type.
NOTE:
The values repoted on this table are
referred at the 12% CO
2
at the mean
sea level and with 0.1 mbar pressure
in the combustion chambre.
PRINCIPLE DIAGRAM DISK-ELECTRODES SETTING
After having installed the nozzle, check the correct position of the electrodes and disk according to the following
levels. It’s adviseable to check levels after every intervention on head.
N.B. To prevent damage to the support effect nozzle assembly/disassembly tasks with
the aid of a wrench and counter-wrench.
N.B. Ignition can be improved under certain
working conditions by slightly adjusting
the position of the electrodes.
000
29
34
11
2
MOD. A B C D
BTL 14P 5 0,5-1 5-5,5 3,5-5
BTL 20P 4,5 0,5-1 5-5,5 3,5-4
BLT 26P 6,5 0,5-1 5-5,5 3,5-4
Burner model
ADJUSTMENT DATA
NOZZLE
TYPE
Pump pressure
Burner flow-rate
3 Servomotor adjustment
2 Disc position
adjustment
GPH
bar
kg/h
50 Hz
60 Hz
Set-point n°
BTL 14P
1,75
12
7,00
5°
3°
2
22
9,00
45°
35°
2
2,50
10
9,50
9°
5°
5,5
22
14,00
90°
70°
5,5
BTL 20P
2,50
10
9,20
5°
3°
0
22
13,40
45°
35°
0
3,00
10
11,20
10°
5°
2,5
22
16,10
90°
70°
2,5
4,00
10
14,75
15°
10°
5
18
20,40
90°
70°
5
4,50
10
16,70
20°
15°
7
16
21,75
90°
70°
7
BTL 26P
4,00
10
14,75
10°
5°
3
22
21,20
90°
70°
3
5,00
10
20,00
22°
9°
7
18
26,80
90°
70°
7
6,00
10
22,40
30°
20°
7
16
27,00
90°
80°
7