Device for bearing diagnostics using shock pulse method
Operation manual
20
Section 4 Operation
Volume adjustment:
To adjust volume press the SET key when the headphones are is
connected, the volume level can be changed with the UP/DOWN keys
from 1 to 10 (Figure 4-6).
Press the M key to return to the headphone mode.
Figure 4-6. Headphone mode.
4.3.
Use of the tester BALTECH VP-3450
4.3.1.
Establishment of equipment monitoring system
In order to obtain accurate and reliable readings using the tester BALTECH
VP-3450 two main requirements should be met:
• Choose a measurement point according to SPM rules;
• Calculate a correct initial dBi value according to a bearing diameter and
rpm.
There are conditions under which the shock pulse measurement doesn’t
provide reliable results:
Low rotation frequency or irregular loads;
Interference from other pulse sources;
Quick damage process;