CONTROL UNIT ASSEMBLY
E -119·462
CONTROL UNIT MOTOR
E-119-462 50/60 Cy. 23. 4 R.P.M. Domestic
E-119-370 50 Cy. only 25 R.P.M. Belgium
----------------------------------
The correct adjustment & synchronization of the Switches controlled by Cam No. 's l0A & 12 is
vitally important to the Replay Counter Circuit. Out of adjustqient Back Switches (12-C & l0A-A) can
cause the four Replay Counters to become overloaded & burn oyt·(affects the Printed Circuit Disc). Fig
ure 3 shows these Cam Switches in a proper "Made" position. '·The Back Switches are adjustable. Note
that the 12-C switch closes first & opens last. Cam Switch
12X
is used for our testing purposes only.
Replay Cam 12 shown in
a normal indexed posi
tion. Switches
12 A,
B,
C are open.
C
12
Cam 12 starting to ro
tate. Switches out of
indexed pos. Switches
A & B are open, Switc;h
C is closed.
C
12
One-half winner
Feature Cam &
Sw,
�
Note: 12A, B, X Switches are now made, Cam #12 Switches A &
Switches 12C & l0A-A are made. All Sw. 's B are now open again,
are centered on lobe & perfectly synchron-
however Switch C is still
.___i_z_ed_. ________________ __, closed. After this cycle
___________ This entire sequence is repeated _______ --=
Cam & Switches return
to the Fig. 1 position
(open).
Adjust Height and Switch
so that the entire bent
part of Switch Blade fits
between Cam Lobes firmly
on Cam & at Cam Center.
I
Ll
Fig.
Replay Cams shown in their
normal Indexed Positions.
Switches are Open.
Arrows point to Lobes that
will actuate Switches.
throughout the scoring cycle.
ADJUSTMENT PROCEDURES
With Replay Cam Index Pill
in Index Cam Notch. Re
play Cam Index must be
adjusted in so that switches
are positioned between
Cam Lobes _as shown.
3/4 of Space from last Lobe
Ll
Fig. 2
Replay Cams shown starting
to Rotate they are now out
of their Indexed Positions.
Switches lG, 2G & 3G are
Open Switch Li is now
Open, Switch Ll is now
Closed.
L l
Fig. 3
Switches lG, 2G & 3G are
now Closed. Switch Ll
Is still closed.
Ll
Fig. 4
Switches IG, 2G & 3G are
now Open again.
Switch LI is still closed.
Ll
Fig. 5
All Switches are now Open
again. Same as in Fig. 1.
This sequence is repeated
thruout Replay Scoring
Cycle.
ALWAYS GIVE MODEL AND PART NO. WHEN ORDERING SERVICE PARTS
15