www.balluff.com
17
english
Device settings
Carrier follow-up time
For hardware version 2.0 or higher, the
Carrier
follow-up time
function no longer exists. The
value does not have any effect.
Follow-up time in seconds of the switched-on antennas
after the command is sent. The read or write command
should be executed within this time after detection.
Factory setting:
5 seconds
Max. number of tags at the same time
Maximum number of expected data carriers in the field.
Factory setting:
128
Ambient
Factor rereadings (only for asynchronous detection or
dynamic mode)
Number of rereadings after which a data carrier is reported
as present (tag coming) or number of failed rereadings
after which a data carrier is reported as not present (tag
going) (only in dynamic mode).
Factory setting:
5
ETSI channels
The channel setting determines the channel assignment. If
multiple channels are activated, the device automatically
selects them by means of the frequency hopping method.
Factory setting:
channel 4 switched on, channels 7…13
switched off
The ETSI channel selection is only available
when using the devices within the European
Union.
Transmitting power
The
Gain
and
Loss
parameters are defined in
the
Antenna type
and
Cable type
fields. These
values are used to determine the maximum
permissible radiated power.
The maximum permissible radiated power and
factory settings differ depending on the set
country profile. For information on the valid
regulations of the different countries, see
In the countries of the European Union, the
radiated power is specified in the form of ERP
(max. 2 watts
ERP
).
In the USA, Canada, Brazil, the radiated power
is specified in the form of an EIRP power (max.
4 watts
EIRP
).
See the “Basic UHF manual” for more
information on radiated powers.
7
Setting the processor unit parameters (continued)
BIS U-6028-048-1_4-06-ST28
Processor unit
Summary of Contents for ProfiNet BIS U-6028-048-104-06-ST28
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 46: ...www balluff com...
Page 87: ...BIS U 6028 048 104 06 ST28 BIS U 6028 048 114 06 ST28 BIS U 6028 048 124 06 ST28...
Page 88: ...www balluff com...
Page 124: ...38 8 16 KA HD 1 1 3 2 2 4 1 00hex 0Fhex KA KA 8 BIS U 6028 048 1_4 06 ST28...