41
BVS Cockpit
Cycle time
The cycle time controls the timing for triggering the IO-Link device. The factory default setting is 0 (Auto). It is recom-
mended that this value be retained. The cycle time is stored in the IO-Link device (slave) and is detected automatically.
Only times that are slower than the automatically selected times can be set manually.
Offset data window and length data window
The offset (offset data window) can be used by the start byte with length (length data window) to define the end byte of
the process data. This setting is only for the input data, has no influence on the actual process data length and is for vis-
ual purposes only.
Validation type
Whether a connected IO-Link device receives access to the IO-Link master can be controlled using validation.
Configuration options:
0
No validation
1
Allows communication to the IO-Link master only for devices whose vendor ID (VID) and device ID (DID) corre-
spond to the configured values.
2
Identical to
1
, in addition the serial number of the IO-Link device is checked.
Vendor ID, VID
Vendor ID for the IO-Link device (refer to the manual for the device)
Device ID, DID
Device ID for the IO-Link device (refer to the manual for the device)
Serial number (SerNum), optional
Serial number for the IO-Link device (if available; refer to the IO-Link device's type plate)
Parameter server, optional
Automatic upload (IO-
Link slave → IO-Link master) or download (IO-Link master → IO-Link slave) can be switched on
using this parameter.
For automatic upload, the parameter configuration is read when an IO-Link device is plugged in. For automatic down-
load, the parameter configuration is transmitted to the device when an IO-Link device is plugged in.
Background:
The automatic upload makes it possible to read in the parameter configuration of a correctly configured device when
plugging one in. If an IO-Link device has to be replaced, the previously read in parameter configuration from the old de-
vice is transferred to the new device when it is plugged in. The Upload option can be disabled by having a valid parame-
ter set read.
Configuration options:
•
Turning on
•
Turning on the upload
•
Turning on the download
Summary of Contents for BVS SC-C1280Z00-30-000
Page 1: ...BVS SC _1280Z00 30 0 0 SMARTCAMERA Fieldbus...
Page 2: ......