![Balluff BVS SC-C1280Z00-30-000 User Manual Download Page 34](http://html1.mh-extra.com/html/balluff/bvs-sc-c1280z00-30-000/bvs-sc-c1280z00-30-000_user-manual_469643034.webp)
34
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
The same applies here again
– when operating the I/O as output, signals of the same name are switched, and when op-
erating as input, I/O of the same name or logically combined with OR.
5.7 Fieldbus interfaces
5.7.1
General fieldbus parameters in BVS Cockpit
The fieldbus parameters are set in the System settings on the Communication tab. Here the selection is also made be-
tween PROFINET or EtherNet/IP. PROFINET is preselected by default. The fieldbus can be changed at any time be-
tween PROFINET and EtherNet/IP.