![Balluff BVS SC-C1280Z00-07-000 User Manual Download Page 26](http://html1.mh-extra.com/html/balluff/bvs-sc-c1280z00-07-000/bvs-sc-c1280z00-07-000_user-manual_469640026.webp)
26
5
Commissioning
BVS SC-_1280Z00-07-0_0
SMART
CAMERA
IO
english
No DHCP server available in the network
In this case, the IP address of the LAN port must be set manually. To do so, you have to connect
with the
SMART
CAMERA
using a PC that is configured for automatically assigned, private IP
address (see “First Steps” on page 21). The settings dialog for the IP address of the
SMART-
CAMERA
is located on the BVS Cockpit web interface under the icon . This option also
allows establishing a connection to the
SMART
CAMERA
if the manually set IP address is not
known.
Notice!
After changing the IP address, the
SMART
CAMERA
may no longer be reachable. In
this case, briefly disconnect the network at the PC and reconnect it.
The network configuration is done in the System settings on the Network tab.
Setting
Description
Obtain an IP address
automatically
It defines whether the IP address of the camera should be assi-
gned dynamically or via DHCP or statically.
IP
If a static IP address is to be used, it can be entered here.
Gateway
If a static IP address is to be used, the gateway can be entered
here. This entry is optional if the same subnet is used exclusively to
access the camera.
Port
The port at which ICS should be listening. Default is Port 80.
Access via
camera name
It determines whether the camera reports itself to other cameras
via its name in the network (see Camera selection).
The
SMART
CAMERA
provides eight internal I/O signals.
Digital inputs and outputs are configured in the System settings on the Digital inputs/outputs tab.
Setting
Description
Name
A user-defined name that describes this input/output.
Direction
It defines whether it is an input or an output. Inputs can be read
out with the
Read inputs
tool. Outputs are set with the
Set outputs
tool.
NOT
If activated, the input/output is inverted. In the inverted state, the
input/output is assumed to be active if no voltage is present.
Note
If the sum of pulse duration and delay exceeds the throughput time of an inspection, it
may lead to undesired effects.
5.5.1 Network Confi-
guration via
BVS Cockpit
5.6
Digital I/O
Interface