![Balluff BVS SC-C1280Z00-07-000 User Manual Download Page 24](http://html1.mh-extra.com/html/balluff/bvs-sc-c1280z00-07-000/bvs-sc-c1280z00-07-000_user-manual_469640024.webp)
24
5
Commissioning
BVS SC-_1280Z00-07-0_0
SMART
CAMERA
IO
english
The following sections describe the configuration of the individual interfaces in detail.
Below is a description of system settings. They can be reached via the System Settings selection
in the system menu.
Figure 22: System menu
The system menu is located in the upper section of the user interface. It consists of the following
menu items:
Menu item
Meaning
User login
Camera selection
System setting
Help system
The process data (results of the image analysis, control of the image acquisition,…) are
exchanged via the LAN interface. The protocol is described in chapter 6, Communication func-
tions of the LAN interface.
The data are transferred as UDP packets via the LAN interface. The pertinent protocol is descri-
bed under "6.1 LAN interface". The UDP port 34701 is used in all cases.
5.2
System
Settings
5.3
Selecting the
Communica-
tion Interface
for the Process
Data