www.balluff.com
2
No. 890045 EN · J17; Subject to modification. Replaces edition 1304.
When mounted, the contact insert protrudes from the
bottom of the square flange by approx. 2 mm.
2
Top view
3.
Fasten the square flange to the hydraulic cylinder using
4 screws. When installed, the connector complies with
protection category IP67.
The pin assignments correspond to the S115
connector and can be found in the user's
guides for the corresponding BTLs.
Square flange
20
5
3
M12x1
Ø 13.3
+0.10 -0.00
14
20
Ø 3.2
Mounting hole
Hydraulic cylinder
The square flange is included in the scope of
delivery.
Installation in hydraulic cylinders
1.
Lead the M12 contact insert through the mounting hole
and out of the cylinder.
2.
Support the contact insert on the 8-mm open-end
wrench. Attach the square flange onto the M12 contact
insert and press it with force until the insert audibly
engages.
8-mm open-end wrench
Square flange
M12 contact insert
BTL5/6/7-…-ZA10 / ZA15
Magnetostrictive Linear Position Sensor – Rod Style
english
Installation