Balluff BTL7 Series Condensed Manual Download Page 4

1

Intended use

The BTL7 Micropulse Transducer, together with a machine 
controller (e.g. PLC), comprises a position measuring 
system. It is intended to be installed into a machine or 

system. Flawless function in accordance with the 
specifications in the technical data is ensured only when 

using original BALLUFF accessories. Use of any other 

components will void the warranty.

Opening the transducer or non-approved use are not 
permitted and will result in the loss of warranty and liability 

claims against the manufacturer.

General safety notes

Installation 

and 

startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the position 
measuring system will not result in hazards to persons or 
equipment.

If defects and unresolvable faults occur in the transducer, it 
should be taken out of service and secured against 
unauthorized use.

Downloading further instructions

A complete user's guide can be downloaded from the 
Internet at 

www.balluff.com

 or requested via e-mail from 

[email protected]

.

Dimensions and function

The BTL7 transducer contains the waveguide which is 
protected by an outer stainless steel tube (rod). A magnet 

is moved along the waveguide. This magnet is connected 
to the system part whose position is to be determined.

english

BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-SR115

Micropulse Transducer - Rod Style

30°

34

40-1

6

Ø D1

Ø 18 h6

60

25

20.5

G

Ø 79

Ø 64

Ø 6.4

Ø 11

94

6

Version

D1

G

…-K-…

10.2 mm

Thread

M4x4/6 deep

…-K8-…

8 mm

No thread

BTL7…-SR115

Mounting 

surface

1) Unusable area
2) Not included in scope of delivery

Damping zone

Magnet

Nominal length =
Measuring range

2)

1)

6 holes for 

mounting the 

transducer

1)

The CE Mark verifies that our products  

meet the requirements of the current  
EMC Directive.

File no.
E227256

Summary of Contents for BTL7 Series

Page 1: ...BTL7 A C E G5 _ _ M _ _ _ _ K 8 SR115 deutsch Kurzanleitung english Condensed guide fran ais Notice r sum e italiano Istruzioni brevi espa ol Instrucciones breves...

Page 2: ...ten und nicht behebbaren St rungen des Weg aufnehmers ist dieser au er Betrieb zu nehmen und gegen unbefugte Benutzung zu sichern Download weiterer Anleitungen Eine ausf hrliche Betriebsanleitung erha...

Page 3: ...e Erdung Wegaufnehmer und Schaltschrank m ssen auf dem gleichen Erdungspotenzial liegen Schirmung Zur Gew hrleistung der elektromagnetischen Vertr glich keit EMV sind folgende Hinweise zu beachten Weg...

Page 4: ...persons or equipment If defects and unresolvable faults occur in the transducer it should be taken out of service and secured against unauthorized use Downloading further instructions A complete user...

Page 5: ...and the control cabinet must be at the same ground potential Shielding To ensure electromagnetic compatibility EMC observe the following Connect the transducer and controller using a shielded cable S...

Page 6: ...t du syst me de mesure de d placement En cas de dysfonctionnement et de pannes du capteur de d placement celui ci doit tre mis hors service et prot g contre toute utilisation non autoris e T l chargem...

Page 7: ...et l armoire lectrique doivent tre reli s au m me potentiel de mise la terre Blindage Pour garantir la compatibilit lectromagn tique CEM les consignes suivantes doivent tre respect es Le capteur de d...

Page 8: ...ra della corsa In caso di difetti e guasti non eliminabili del trasduttore di posizione questo deve essere disattivato e protetto contro l uso non autorizzato Download di ulteriori istruzioni Per il m...

Page 9: ...l armadio elettrico devono trovarsi sullo stesso potenziale di terra Schermatura Per garantire la compatibilit elettromagnetica CEM necessario rispettare le seguenti avvertenze Collegare il trasduttor...

Page 10: ...e defectos y fallos no reparables en el transductor de desplazamiento ste se debe poner fuera de servicio e impedir cualquier uso no autorizado Descarga de otros manuales Usted obtendr un manual de in...

Page 11: ...tar a id ntico potencial de puesta a tierra Blindaje Para garantizar la compatibilidad electromagn tica CEM se deben tener en cuenta las siguientes indicaciones Conecte el transductor de desplazamient...

Page 12: ...C BALLUFF www balluff com service balluff de BTL7 BTL7 A C E G5 _ _ M _ _ _ _ K 8 SR115 30 34 40 1 6 D1 18 h6 60 25 20 5 G 79 64 6 4 11 94 6 D1 G K 10 2 mm M4x4 6 K8 8 mm BTL7 SR115 1 2 2 1 6 1 CE EMV...

Page 13: ...m 8 mm 11 mm f f f f f f 1 2 3 EMC 85 BTL7 A G 30 m 1 BTL7 C E 100 m 1 1 f f f f A510 G510 C500 C570 E500 E570 SR115 8 M12 1 0 V 3 1 2 0 V 5 3 10 0 V 10 10 V 1 1 GND 2 EMC GND 4 La 5 0 10 V 10 10 V 0...

Page 14: ......

Page 15: ......

Page 16: ...9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390...

Reviews: