Type code breakdown
BTL7 - E 5 08 - M0500 - P - S32
Micropulse transducer
Interface:
C = Analog interface, current output 0…20 mA or 20…0 mA (factory setting)
E = Analog interface, current output 4…20 mA or 20…4 mA (factory setting)
Supply voltage:
5 = 10…30 V DC
Output gradient:
08 = 1 rising current output, config 1 rising voltage output
09 = 1 rising current output, config 1 falling voltage output
12 = 1 falling current output, config 1 rising voltage output
13 = 1 falling current output, config 1 falling voltage output
Nominal stroke (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm (M0050…M7620)
Construction:
P = profile housing
Electrical connection:
S32 =
8-pin, M16 plug per IEC 130-9
KA05 = Cable, 5 m (PUR)
BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing