www.balluff.com
11
english
Fig. 4-9:
Magnet
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Example 2, BTL installed with supporting rod (only for
BTL7…-TB/TZ….)
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector (BTL7...-S32, BTL7...-S135)
The connection or pin assignments for the respective
version can be found in Tables 4-2 to 4-5.
Note the information on shielding and cable
routing on page 12.
4
Installation and connection (continued)
4.4.1 Connector S32/cable connection
S32
Pin
Wire color
BTL7-… interface
Fig. 4-10: Pin assignment of S32
connector (view from above on
BTL), 8-pin M16 circular plug
-A504
-G504
-C504
-E504
1
YE yellow
Not used
1)
0
…
20 mA
2)
4
…
20 mA
2)
2
GY gray
0 V
3
PK pink
Not used
1)
4
RD red
La (communication line)
5
GN green
0
…
10 V
2)
–
10
…
10 V
2)
Not used
1)
6
BU blue
GND
3)
7
BN brown
10
…
30 V
8
WH white
Lb (communication line)
Tab. 4-2: Connection assignment BTL7-A/C/E/G504-…-S32/cable
S32
Pin
Wire color
BTL7-… interface
Fig. 4-11: Pin assignment of S32
connector (view from above on
BTL), 8-pin M16 circular plug
-A505
-G505
-C505
-E505
1
YE yellow
Not used
1)
20
…
0 mA
2)
20
…
4 mA
2)
2
GY gray
0 V
3
PK pink
Not used
1)
4
RD red
La (communication line)
5
GN green
10
…
0 V
2)
10
…
–
10 V
2)
Not used
1)
6
BU blue
GND
3)
7
BN brown
10
…
30 V
8
WH white
Lb (communication line)
Tab. 4-3: Connection assignment BTL7-A/C/E/G505-…-S32/cable
1)
Unassigned leads can be connected to the GND on the controller side but not to the shield.
2)
Factory setting, can be freely configured with the PC software.
3)
Reference potential for supply voltage and EMC-GND.
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style