Startup
5.1
Check connections
Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
5.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6
Noise elimination
To avoid a equipotential bonding - a
current flow - through the cable
shield, we recommend that putting
the control cabinet and the system
in which the BTL6 is located at the
same ground potential.
5.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other* than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifica-
tion or manufacturing tolerances.
5.4
Check functionality
The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
6.1
Included in shipment
Transducer with short guide incl.
O-ring and support ring.
6.2
Available stroke lengths
and magnets
Part No.
Stroke length
Increment
BTL6...-E2-
50 ... 1500 mm 5 mm
BTL6...-E28-
50 ... 1016 mm 5 mm
Special lengths on request.
6
Versions (indicated on part label)
Supply voltage
5 = DC 10...30 V
Electr. connection: KA02:
axial centric with 2 m cable
KE02:
axial eccentric with 2 m cable
LA00,3:
axial with 0.3 m long leads
BTL6-E500-M0450-E28-KA02
thinner rod (if applicable)
8 =
∅
8 mm
Rod construction, pressure tube
∅
10.2 mm
Mounting: Plug flange
Nom. length (4 digits): M = metric in mm
Interface: E = 4...20 mA
Micropulse
Linear T
ransducer
7.1
Magnets
Magnet BTL-P-1013-4R,
BTL-P-1012-4R
Dimensions
➥
➥
➥
➥
➥
Fig. 3-5
Weight
approx. 10 g
Housing
anodized
aluminum
Operating temp.
–40 °C to +85 °C
included in shipment
Spacer
8 mm
Material
POM (Polyoxymethylene)
7
Accessories (order separately)
Magnet BTL-P-1014-2R
Dimensions
➥
➥
➥
➥
➥
Fig. 3-5
Weight
approx. 10 g
Housing
anodized
aluminum
Operating temp.
–40 °C to +85 °C
Magnet BTL-P-GR-PAF
Dimensions
➥
➥
➥
➥
➥
Fig. 3-5
Weight
approx. 2 g
Housing
PA
Operating temp.
–40 °C to +85 °C