background image

WWW.BALLUFF.COM 

 • 

 1-800-543-8390

BTL5-P/I/K/L/M_-

M/U_ _ _ _-P-S32/KA_ _

Micropulse Linear Transducer

Digital Output / Profile Housing

3   Installation (cont.)

Fig. 3-5: Dimensional drawing (BTL5...P-KA transducer with captive magnet BTL5-F-2814-1S)

Mounting brackets with isolation bushings and M5 x 22
cylinder head screws, DIN 912,
max. tightening torque 2 Nm

Black,
round
marking

NL

Nominal stroke

Ball joint "B"
DIN 71805,
rotates horizontally

Black, round
marking

Fig. 3-6: BTL5-F-2814-1S magnet

Fig. 3-7: BTL5-M/N-2814-1S magnet

Mechanically joined to M5
stud using 2 nuts

Max. angle offset

Max. parallel offset

BTL5-M-2814-1S:

X = 48.5

Y = 57

BTL5-N-2814-1S:

X = 51

Y = 59.5

3.3   Captive magnets

Lateral forces are to be avoided
when using captive magnets
(Figs. 3-6 and 3-7). Connections
are required here which permit the
corresponding degree of freedom
with respect to the direction of
movement of the magnet along
the stroke range. It is assumed
that the BTL5-F-2814-1S magnet
is connected to the machine
member using a connecting rod.
The BTL2-GS08...A connecting
rod (Fig. 3-8) is available as an
accessory (please indicate length
LS when ordering).

Jam nut DIN 934 M5

Swivel eye DIN 648

Ball joint "B" DIN 71805,
rotates horizontally (part of
BTL5-F-2814-1S) magnet)

Fig. 3-8: BTL2-GS08-_ _ _ _-A
connecting rod

Summary of Contents for BTL5-P

Page 1: ...Sensors Worldwide BTL5 P I K L M_ M U_ _ _ _ P S 32 KA_ _ Micropulse Linear Transducer Digital Output Profile Housing Technical Description User s Guide...

Page 2: ......

Page 3: ...stop with tri state Differential stop leading edge active Differential pulse width modulated Differential start stop leading edge active Single ended start stop leading edge active Differential start...

Page 4: ...stallation 3 3 2 Floating magnets 4 3 3 Captive magnets 5 4 Wiring 6 5 Startup 7 5 1 Check connections 7 5 2 Turning on the system 7 5 3 Check output values 7 5 4 Check functionality 7 5 5 Fault condi...

Page 5: ...provides an unreliable signal but which may be entered The electrical connection between the transducer the processor controller and the power supply is via a cable which depending on the version is...

Page 6: ...is attached to the moving member of the machine using non magnetizable screws brass aluminum To ensure the accuracy of the transducer system the moving member must carry the magnet on a track paralle...

Page 7: ...5 stud using 2 nuts Max angle offset Max parallel offset BTL5 M 2814 1S X 48 5 Y 57 BTL5 N 2814 1S X 51 Y 59 5 3 3 Captive magnets Lateral forces are to be avoided when using captive magnets Figs 3 6...

Page 8: ...d power supply avoid proximity to high voltage lines to prevent noise coupling Especially critical is inductive noise caused by AC harmonics e g from phase control devices against which the cable shie...

Page 9: ...the replacement or repair are found a correction should be made Transducers are subject to modification or manufacturing tolerances 5 4 Check functionality The functionality of the transducer system...

Page 10: ...Overvoltage protection Transzorb diodes Electric strength GND to housing 500 V Control arm optional BTL2 GS08 _ _ _ _ A Aluminum dimensions Fig 3 8 Various standard lengths LS available please specify...

Page 11: ...gs and M5 x 22 cylinder head screws DIN 912 max tightening torque 2 Nm NL Nominal stroke Fig 3 2 BTL5 P 3800 2 magnet Fig 3 4 BTL5 P 4500 1 electromagnet 24 V 100 mA Fig 3 3 BTL5 P 5500 2 magnet max p...

Page 12: ...th American Headquarters Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 Web www balluff com E Mail balluff balluff com Canada Balluff Cana...

Reviews: