www.balluff.com
63
english
6.5.4 ISDU
Minimum
,
Maximum
,
Average
and
Moving
Average outputs
are output in FLOAT32 format.
Before they are processed further and converted
from FLOAT32 to INT32 or UINT32, the output
signal must be checked to determine whether it
is larger than INT32_Max or UINT32_Max. If it is
larger, data type UINT64 or INT64 should be
used.
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Statistics Data Configuration
0x0426
(1062)
0
R/W
8 bytes
Yes
Input Signal
1
R/W
2 bytes
UINT16(ENUM)
No
0
Time Period Unit
2
R/W
1 byte
UINT8(ENUM)
No
Seconds
Time Period Value
3
R/W
2 bytes
UINT16
No
1
Moving Average Window Unit
4
R/W
1 byte
UINT8(ENUM)
No
Measurement
values
Moving Average Window
Value
5
R/W
2 bytes
UINT16
No
100
Statistics Data Output
0x0427
(1063)
0
R
21 bytes
n/a
Minimum
1
R
4 bytes
FLOAT32
n/a
–
Maximum
2
R
4 bytes
FLOAT32
n/a
–
Average
3
R
4 bytes
FLOAT32
n/a
–
Moving Average
4
R
4 bytes
FLOAT32
n/a
–
Number of samples
5
R
4 bytes
UINT32
n/a
–
Status
6
R
1 byte
UINT8
n/a
–
Tab. 6-24: Basic statistics – ISDU
Statistics Data Configuration: Input Signal
All data types of process data objects can be used for
input configuration, with the exception of Boolean. The
respective Object IDs can be found in the respective
section on the function. Default value is 0,
this corresponds to
no object
.
Statistics Data Configuration: Time Period Unit
The time unit
Time Period Unit
can be set with one of the
values from Tab. 6-25 to calculate the minimum, maximum
and average. For example, to calculate minimum,
maximum and average for all 1-hour values, hours can be
selected as the unit for this subindex.
Value
Meaning
Description
0x01 (1)
Seconds
Seconds
0x02 (2)
Minutes
Minutes
0x03 (3)
Hours
Hours
0x04 (4)
Days
Days
0x05 (5)
Samples
Measurement
values
Tab. 6-25: Statistics Data Configuration – Time Period Unit
6
Secondary Device Functions (continued)
BOS R254K-UUI-RH11-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH11-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH11 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH11 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH11 S4 Configuration Guide english...
Page 110: ...www balluff com...