16
english
3.4
ISDU – Identification Data
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Identification
Vendor Name
0x0010
(16)
0
R
7 bytes
STRING
n/a
“Balluff”
Vendor Text
0x0011
(17)
0
R
15 bytes
STRING
n/a
“www.balluff.com”
Product Name
0x0012
(18)
0
R
[…]
STRING
n/a
“BOS R254K-UUI-
RH11-S4 (ADSS)”
Product ID
0x0013
(19)
0
R
[…]
STRING
n/a
“BOS R254K-UUI-
RH11-S4 (ADSS)”
Product Text
0x0014
(20)
0
R
[…]
STRING
n/a
“Background
suppression red
light”
Serial Number
0x0015
(21)
0
R
16 bytes
STRING
n/a
Hardware Revision
0x0016
(22)
0
R
2 bytes
STRING
n/a
Firmware Revision
0x0017
(23)
0
R
≤ 10 bytes
STRING
n/a
Application Specific
Tag
0x0018
(24)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Function Tag
0x0019
(25)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Location Tag
0x001A
(26)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Product Type Code
0x0700
(1792)
0
R
≤ 64 bytes
STRING
n/a
“BOS R254K-UUI-
RH11-S4 (ADSS)”
Product Order Code
0x0701
(1793)
0
R
7 bytes
STRING
n/a
“BOS02C4”
Device Identification
Device Discovery
Timeout
0x00FE
(254)
0
R/W
2 bytes
UINT16
Yes
1
Optical Frontend
Optical Frontend
0x01B2
(434)
0
R
4 bytes
Transducer Value
1
R
4 bytes
INT32
No
Switching profiles (AdSS)
SSC Parameter SP
0x0038
(56)
0
R/W
2 bytes
INT16
Yes
0x03E8 (1000)
SSC Configuration
Logic
0x0039
(57)
0
R/W
1 byte
UINT8
Yes
0x00
Teach-In Result
0x003B
(59)
0
R
1 byte
UINT8
n/a
–
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-RH11-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH11-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH11 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH11 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH11 S4 Configuration Guide english...
Page 110: ...www balluff com...