No. 852592 E Edition G17; Replaces edition 1111
6XEMHFWWRPRGL¿FDWLRQ
15
Mounting and
operating instructions
No. LED
Description
Factory setting
3
Q
A
V
N
C
QA
OK
FS
Switch operating mode (speed mode / averaging mode)
Press
T
until the „Av“ LED lights up.
The operating mode (speed / averaging) is changed by pressing
S
repea-
tedly.
Look at the „ZA“ LED (red). „ZA“ lights = averaging mode is active.
„ZA“ does not light = speed mode is active.
Exit the Set menu (
T
+
S
) or
go to the next setting with the
T
button.
$YHUDJLQJ0RGHIRUGHWHFWLQJURXJKVXUIDFHV7KHDULWKPHWLFÀRDWLQJ
average of 100 measured values is taken. This smoothes the measu-
ring result.
Speed Mode: for shortest response time and max. switching frequency
without averaging.
speed mode
4
Q
A
V
N
C
QA
OK
FS
N.O./N.C. switching
Press
T
until the „Nc“ LED lights.
The switching function (N.O/N.C) is changed by pressing
S
repeatedly.
Look at the „ZA“ LED (red): „ZA“ lights = switching type N.C. is active.
„ZA“ does not light = switching type N.O. is active.
Exit the Set menu (
T
+
S
) or
go to the next setting with the
T
button..
N.O.
5
Q
A
V
N
C
QA
OK
FS
Activate Factory Setting
Press
T
until the „FS“ LED lights.
Press
S
once.
The sensor is reset to the factory state.
7KHÄ=$³/('OLJKWVIRUFRQ¿UPDWLRQIRUDVORQJDV
S
is pressed.
Exit the Set mode (
T
+
S
) or
go to the next setting with the
T
button.
'HDFWLYDWLQJWKH6HW0RGH([LW
First press
T
, then
S
. All settings are then saved. The sensor is in the Run mode after releasing the buttons. The
operating indicator „BA“ (green) lights steadily