Mounting and  
operating instructions

,OOXVWU

15501560

Operation and Setting

6.1 

Possible Settings and Operating Modes

The BOD 26K is ready to operate after applying the operating voltage. 
However, the following settings can be made if necessary:

· Set the switching point or switching window
· Scale the analogue output
· Set the operating mode (Speed Mode / Averaging Mode )
· Set the switching type (N.O./N.C)
· Reset the sensor to the factory state
· Laser off and measured value hold (via electrical connection)
· Lock buttons „S“ and „T“ (via electrical connection)

6.2 

Factory State:

· Switching output: 

Switching output is active when the object is in the operating range and reliably detected. Switching type = N.O.

· Analogue output (4...20 mA): 4 mA = end of operating range, 20 mA = beginning of operating range
· Operating mode = speed mode (shortest response time)
· Operation = free running (normal mode)

6.3 

Indicators and Setting Elements

The BOD 26 K  is set with the buttons S and T.

S

Set button:

&KDQJHRUFRQ¿UPVHWWLQJRUWHDFKLQVZLWFKLQJSRLQW

T

Toggle 
button:

Select setting, jumps one setting forward.

S

T

Con

f

Exi

t

Conf 
and 
Exit

Pressing both buttons simultaneously causes: 
3 s Conf  

=> activate set mode

1x press Exit 

=> data are saved and the setting mode exited

The LEDs indicate the selected settings.

LED

Colour

Use

Description

BA

Green

Operating indicator

On: ready for operation (Run mode)
Flashing: Set mode is active

ZA 

Red

Status indicator  
(only active in the Set mode)

Lights: selected setting is active

Q

Yellow

Indicates status of output Q

Lights: switching output active

QA

Yellow

Indicates status of output QA

Lights: object is within the set  0% and  
100 % range

Av

Green

Signals operating mode  
(speed/averaging)

Lights: operation set with averaging

OK

Green

Stability indicator (good target)

Lights: object safely detected and in the 
operating range

Nc

Green

Signals switching type N.O./ 
N.C.for output Q

Lights: switching type N.C. set

FS

Green

Factory Setting  
(only active in Set mode)

Lights: factory setting selected

BA

ZA

S

Q

A

V

N

C

QA

OK

FS

ti

x

E

f

n

o

C

Summary of Contents for BOD 26K Series

Page 1: ...bstandssensor Distance sensor Capteur de distance Montage und Bedienungsanleitung Mounting and operating instructions Instructions de service et de montage BOD 26K LB06 S92 C BOD0007 LB07 S92 C BOD000...

Page 2: ...drawings and the layout be copied without prior written permission from Balluff GmbH We accept no responsibility for printing errors and mistakes which occurred in drafting this manual Subject to del...

Page 3: ...U Maschinenrichtlinien Der BOD 26K entspricht der Laserschutzklasse 2 nach IEC 60825 1 Die technischen Anforderun gen gen gen der EN 60947 5 2 Entspricht 21 CFR 1040 10 und 1040 11 mit Ausnahme der Ab...

Page 4: ...p X mm BOD 26K LB06 S92 C 18 4 BOD 26K LB07 S92 C 21 5 Abb 1 15300716 Sensoranordnung BOD 26K positionieren so dass der Abstand zum Objekt innerhalb des Arbeitsbereiches des Sensors liegt Den BOD 26K...

Page 5: ...n UB Versorgungsspannung 2 WH Weiss QA Analogausgang 4 20 mA 3 BU Blau 0V Versorgungsspannung 4 BK Schwarz Q Schaltausgang 5 GY Grau IN Steuereingang Laser Disable Tastenverriegelung Freilaufend wenn...

Page 6: ...ellelemente Der BOD 26K wird mit den Tasten S und T eingestellt S Set Taste Einstellung ndern bzw best tigen oder Schaltpunkt teachen T Toggle Taste Einstellung ausw hlen springt eine Einstellung weit...

Page 7: ...den Teachpunkt gelegt Schaltfenster ber den gesamten Arbeitsbereich d h Schaltausgang ist aktiv wenn Objekt im Arbeitsbereich und sicher erfasst ist 2 Q AV NC QA OK FS Skalieren des Analogausgangs QA...

Page 8: ...uenz ohne Mittelung speed mode 4 Q AV NC QA OK FS N O N C Schliesser ffner Umschaltung T bet tigen bis die LED Nc leuchtet Die Schaltfunktion N O N C wird durch wiederholtes Dr cken von S gewechselt L...

Page 9: ...ohne Last P EHL 9 Schaltausgang Q PNP N O N C umschaltbar Ausgangsstrom Q P Schaltfrequenz Q N VSHHG PRGH DYHUDJLQJ PRGH Ansprechzeit Q QA 0 4 ms speed mode 40 ms averaging mode Max kapazitive Last Q...

Page 10: ...is not a safety component as described by EU machine directives The BOD 26K sensor complies with laser protection class 2 according to IEC 60825 1 The technical requirements comply with EN 60947 5 2...

Page 11: ...s within the operating range of the sensor Screw the BOD 26K sensor to the mounting bracket e g type BOS 26 HW 1 not included in delivery or a suitable device Only use the holes provided in the housin...

Page 12: ...tage 2 WH White QA analogue output 4 20 mA 3 BU Blue 0V supply voltage 4 BK Black Q switching output 5 GY Grey IN control input Laser Disable Button lock Free running when HIGH UB when LOW 0V when ope...

Page 13: ...tors and Setting Elements The BOD 26 K is set with the buttons S and T S Set button KDQJH RU FRQ UP VHWWLQJ RU WHDFK LQ VZLWFKLQJ SRLQW T Toggle button Select setting jumps one setting forward S T Con...

Page 14: ...ng window 1 of the operating range is laid around the teach point Switching window over the whole operating range i e switching output is active when the object is in the operating range and reliably...

Page 15: ...or shortest response time and max switching frequency without averaging speed mode 4 Q AV NC QA OK FS N O N C switching Press T until the Nc LED lights The switching function N O N C is changed by pre...

Page 16: ...consumption no load P DW 9 Signal output Q PNP N O N C selectable Output current Q P Switching frequency Q N VSHHG PRGH DYHUDJLQJ PRGH Response time Q QA 0 4 ms speed mode 40 ms averaging mode Maximum...

Page 17: ...SDUHLO QH VRQW SDV SHUPLVHV H 2 Q HVW SDV XQH SLqFH GH VpFXULWp DX VHQV GHV GLUHFWLYHV 8 UHODWLYHV DX PDFKLQHV H 2 FRUUHVSRQG j OD FODVVH GH SURWHFWLRQ GH ODVHU VHORQ HV H LJHQFHV techniques satisfont...

Page 18: ...C 18 4 BOD 26K LB07 S92 C 21 5 Fig 1 15300716 Positionnement du capteur Positionner le BOD 26K de mani re ce que sa distance l objet soit comprise dans le champ de travail du capteur Fixer le BOD 26K...

Page 19: ...WH Blanc QA Sortie analogique 4 20 mA 3 BU Bleu 0V Tension d alimentation 4 BK Noir Q Sortie de commutation 5 GY Gris IN Entr e de contr le Laser Disable Verrouillage de touche Libre si HIGH UB si LO...

Page 20: ...H UpJODJH Le BOD 26K se r gle avec les touches S et T S Touche Set 0RGL HU RX FRQ UPHU OH UpJODJH RX LQLWLDOLVHU OH SRLQW GH FRPPXWDWLRQ SDU DSSUHQWLVVDJH T Touche Toggle S lectionner le r glage Passe...

Page 21: ...de commutation une fen tre de commutation minimum 1 du champ de travail sera tablie autour du point d apprentissage La fen tre de com mutation est active sur l ensemble du champ de travail sortie de...

Page 22: ...tation maximale sans moyennage speed mode 4 Q AV NC QA OK FS N O N C contact fermeture contact ouverture commutation Actionner T jusqu ce que la LED Nc s allume Basculer la fonction de commutation N O...

Page 23: ...Consommation sans charge P SRXU 9 Sortie de commutation 313 1 2 1 FRQ JXUDEOH Courant de sortie Q1 Q2 P Fr quence de commutation Q1 Q2 N VSHHG PRGH DYHUDJLQJ PRGH Temps de r ponse Q1 Q2 QA 0 4 ms spe...

Page 24: ...Kontaktadressen Contact addresses Contacts Deutschland Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Tel 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 E Mail balluff balluff de www balluff de...

Reviews: