Summary of Contents for BNI IOL-800-000-Z036

Page 1: ...BNI IOL 800 000 Z036 BNI IOL 800 000 Z037 Smart Light User s Guide...

Page 2: ...t description of the functionality 8 3 8 Segment mode 8 3 9 Runlight mode 8 3 10 Flexible mode 8 3 11 Synchronisation 8 4 IO Link Interface 9 4 1 IO Link Data 9 4 2 Process data Output data 9 BNI IOL...

Page 3: ...e IO Link BNI IOL 800 000 Z03x www balluff com 2 5 3 Electrical data 16 5 4 Operating conditions 16 5 5 LED indicator 17 Status LED 17 6 Appendix 18 6 1 Product ordering code 18 6 2 Order information...

Page 4: ...tion result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross referenc...

Page 5: ...ded use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this opera...

Page 6: ...5 3 Getting Started 3 1 Overview BNI IOL 800 000 Z036 Fig 3 1 BNI IOL 800 000 Z036 1 Cap 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7 LED4 8 LED3 9 LED2 10 LED1 1 2 3...

Page 7: ...Z03x www balluff com 6 3 Getting Started 3 2 Overview BNI IOL 800 000 Z037 Fig 3 2 BNI IOL 800 000 Z037 1 Cap with buzzer 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7...

Page 8: ...nection IO Link M12 A coded male Pin Function 1 Power supply controller 24V 2 3 GND reference potential 4 C Q IO Link Data transmission channel Smart Light connection Connection protection ground to F...

Page 9: ...nlight mode In the runlight mode the complete module displays a running light effect In this case all of the LEDs are working as one runlight effect The runlight mode is controlled by ISDU registers T...

Page 10: ...epending on the selected mode segment mode runlight mode or flexible mode BNI IOL 800 000 Z03x Segment Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start Segment 1 blink...

Page 11: ...Bit 5 6 Sync start Sync impulse available from software version 3 0 These bits are rising edge sensitive BNI IOL 800 000 Z03x Flexible Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync im...

Page 12: ...32 Byte string adjustable by the user Parameter Data ISDU Object name Length Range Default Value Index Sub index 40hex 0 Mode 1 Byte 0 or 2 0 4Dhex 0 Runlight mode background color 1 Byte 0 7 0 4Ehex...

Page 13: ...ption Background color The background of the runlight effect can be set in this register Bit 0 2 Background color 000 Off 001 Green 010 Red 011 Yellow 100 Blue 101 Orange 110 User defined 111 White Ru...

Page 14: ...This register sets the brightness for each channel red green and blue Values from 0x00 to 0x7F are accepted for each channel This register can be accessed through the subindices 0 1 2 or 3 Reading wr...

Page 15: ...y cycle or flash The blinking of the desired segment must be activated in process data to enable blinking Flexible mode LEDx settings A1hex A4hex This register contains the settings for the flexible L...

Page 16: ...el User defined color green channel User defined color green channel Buzzer type FEhex This register is available only for BNI IOL 800 000 Z037 The type of the buzzer sound can be set in this register...

Page 17: ...800 000 Z036 117 60 60 mm BNI IOL 800 000 Z037 138 5 60 60 mm 5 3 Electrical data Operating voltage 18 30 2 V DC per EN 61131 2 Ripple 1 Current draw all segments off 30 mA 24V Current draw all segmen...

Page 18: ...tus for supply and communication The status LED indicates the current status of the power supply and the communication It can be switched on switched of and flashing Communication error Communication...

Page 19: ...consists of the following components signal light M18x1 nut rubber foot screw M4 spring washer user s guide BNI IOL 800 000 Z03x Balluff Networking Interface IO Link Interface 800 Smart Light 1 Segme...

Page 20: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 915739 726 EN 06 123333 Edition L16 Replaces Edition K15 Subject...