www.balluff.com
9
4
IO-Link Interface
4.1
IO-Link Data
BNI IOL-800-000-Z03x
Data transmission rate
COM2 (38,4 kBaud)
Minimal cycle time
5 ms
Process data length
1 Byte output
IO-Link Revision
1.1
1.0
Frame type
2.V
1
Process data cycle time* 5 ms
5 ms
* by min. cycle time
4.2
Process data /
Output data
The BNI IOL-800-000-Z036 and BNI IOL-800-000-Z037 Smart Light modules have 1 byte
output process data. The output process data has different meaning depending on the
selected mode (segment mode, runlight mode or flexible mode).
BNI IOL-800-
000-Z03x,
Segment Mode
Byte
0
Bit
7
6
5
4
3
2
1
0
D
es
cri
pt
ion
B
uz
ze
r
s
ta
te
S
yn
c
impu
ls
e
S
yn
c
st
ar
t
-
S
eg
men
t 1
b
lin
k
S
eg
men
t 1
co
lor
Bit definitions
in segment
mode
Bit 0-2, Segment color
000 = Off
001 = Green
010 = Red
011 = Yellow
100 = Blue
101 = Orange
110 = User defined
111 = White
Bit 5/6, Sync start/Sync impulse
(available from software version 3.0)
These bits are rising edge sensitive
Bit 3, Segment blink
0 – Segment does not blink
1 – Segment blinks according to the blink
modus settings
Bit 7, Buzzer state
(Only in case of BNI IOL-800-000-Z037)
0 – buzzer is off