16
english
6
Analog interface and switching output (continued)
6.4
Settings using the button
Fig. 6-6:
2
s
2
s
2
s
2
s
2
s
2
s
2
s
Adjusting the analog output
Green on/off
Green on = Voltage output
Yellow 2 Hz
Green off = Current output
Red 2 Hz
Convert: Press the button briefly
Range teach minimum
Green off
Yellow off
Red 2 Hz
Range teach maximum
Green off
Yellow 2 Hz
Red off
Adjusting the edge
Green on/off
Green on = Falling edge
Yellow off
Green off = Rising edge
Red 5 Hz
Convert: Press the button briefly
Teach switch point
Green off
Yellow 5 Hz
Red off
Adjusting the switch point logic
Green on/off
Green on = Normally closed
Yellow 5 Hz
Green off = Normally open
Red 5 Hz
Convert: Press the button briefly
Resetting to factory settings
Green 5 Hz
Yellow off
Red off
Normal operation
2
s
2
s
Calibration mode
Green 2 Hz
Yellow 2 Hz
Red 2 Hz
Setup error
All LEDs flash for 3 s at 5 Hz
(asynchronous)
Legend
Press the
button briefly
2
s
Hold the button
for 2 s
1 ×
2 ×
3 ×
4 ×
5 ×
6 ×
7 ×
The settings made using the button apply to the
operation using the analog as well as IO-Link
interface.
Overview of setup mode
BMP 01-EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
Summary of Contents for BMP 01-EL1PP 1A Series