www.balluff.com
Accuracy
The specifications are typical values for
BIP-A/CD2-T017-01-EB/EP _ _ (-S4/S49) at room
temperature. The BIP reaches its full accuracy after a
warm-up period of 15 min under constant ambient
conditions. The duration of warm-up depends on the
ambient conditions.
Measuring range S
l
0…17 mm
Linearity range S
l
0…17 mm
Max. non-linearity
±250 µm
Reference distance S
e
8.5 mm
Repeat accuracy
±50 µm
Sampling rate
≥ 600 Hz
Response time
2.5 ms
Ambient conditions
1)
Ambient temperature T
a
BIP AD2-T017-01-EB/EP_ _
BIP CD2-T017-01-EB/EP_ _
–25…+70 °C
–10…+70 °C
Storage temperature
–40…+85 °C
Temperature drift max. from end
value
±3 %
Degree of protection per IEC 60529
IP67
Shock rating
per EN 60068-2-27
30 g/11 ms
Vibration load
per EN 60068-2-6
55 Hz, 1 mm
amplitude,
3 × 30 min
Degree of contamination
3
Supply voltage (external)
Operating voltage
U
B
, stabilized
2)
15…30 V DC
Rated operating voltage U
e
24 V DC
No-load current I
o
at U
e
≤ 20 mA
Residual ripple (% of U
e
)
≤ 10 %
Rated insulation voltage U
I
75 V DC
Short-circuit protection
Yes
Protected against miswiring
Yes
Polarity reversal protected
Yes
Output
BIP AD2-T017-01-EB/EP_ _
Output voltage at S
l
Output voltage at S
e
Load resistance R
L
0…10 V
5 V
≥ 2000 Ω
BIP CD2-T017-01-EB/EP_ _
Output current at S
l
Output current at S
e
Load resistance R
L
4…20 mA
12 mA
≤ 500 Ω
No. 941909 EN · K20; Subject to modification. Replaces G20.
4
english
Mechanical
Connection type
BIP A/CD2-…-EB/EP _ _
BIP A/CD2-…-EB/EP _ _ -S4
BIP A/CD2-…-EB/EP _ _ -S49
Cable
Cable with S4
connector
Cable with S49
connector
Housing material
PA
Tightening torque
0.5 Nm
Sensing surface, material
PA
Cable connection
Cable jacket, material
PUR
Cable diameter
≤ 3.5 mm
Number of conductors
3
Wire cross-section
0.14 mm²
Shielding
BIP A/CD2-…-EB_ _
BIP A/CD2-…-EP_ _
Yes
No
Bending radius, fixed cable
≥ 3 x cable
diameter
1) For UL: Use in enclosed spaces and up to a height of 2000 m above sea
level.
2) For UL: The BIP must be externally connected via a limited-energy circuit
as defined in UL 61010-1, a low-power source as defined in UL 60950-1
or a class 2 power supply as defined in UL 1310 or UL 1585.
Accessories
BAM TG-XE-020 target
(order code: BAM02RW)
The position detected by the BIP (
A
) lies in the center
of the target (line of symmetry).
Material:
Steel (EC-80)
5
18
10
6
27
28
A
BAE PD-XE-005 calibration box
(order code: BAE00T3)
Technical data
BIP A/CD2-T017-01-EB/EP _ _ (-S4/S49)
Inductive Position System