Balluff Inductive Coupler
BIC 1I22-P2A02-M18MN2-EPX07-050 (Base)
BIC 2I22-P2A02-M18MF2-EPX07-050 (Remote)
www.balluff.com
4
2
System Overview
2.1 Topology
The BIC system transmits 4 binary signals from the mobile unit (Remote) via the air gap to the
stationary unit (Base). In addition to this signal transmission, the BIC system provides electric
power to the sensors connected to the Remote. The maximum permissible transmission
distance between Base and Remote is 3mm at a permissible offset of
±
3mm
Signal
Power
SPS
Sensor
Sensor
Sensor
Sensor
Base
Remote
The components are housed in an IP 67 protected brass enclosure
Sensors
For the standard version of electronic sensors, observe the following:
•
Be sure that the total current draw of the sensors is not greater than 100mA.
•
Only use sensors with a voltage of 12 V DC.
Mechanical switches
For the standard version of mechanical switches, observe the following:
•
Use switches for small load currents
•
Use switches with a residual current I <0.1 mA in the open switching state
•
The total resistance of the circuit should be less than 1 kOhm
2.2 Base
indicators
Signaling
Function
Green, static
Supply voltage OK Remote coupled
Green, flashing slowly
Supply voltage OK, no Remote
Green, rapidly flashing
Overload/short-circuit
2.3 Remote
indicators
Signaling
Function
Green, static
Supply voltage OK
Green, rapidly flashing
Overload/short-circuit