background image

 

 

  www.balluff.com 

   

     9 

4

 

Technical Data 

4.2  Remote 

 

 

 

 

 

LED 

 

LED 

Indicator 

Function 

Green 

Static 

Connection established 

Fast flashing 

Overload/short-circuit 

 

 

 

Mechanical data 

 

Housing material 

Brass, CuZn coated 

Thread 

M18 x 1 

Sensing surface material 

PA 66 

Housing degree of protection 

IP 67  

Weight 

310 g 

Dimensions (D x L in mm) without 
pigtail 

M18 x 61 

Pigtail 

Cable PUR 7x0.34

2

 

 

 

 

Electrical data 

 

Operating voltage 

12 V DC ±10% 

No. of digital inputs  

4 x PNP 

Operational readiness  

 80ms 

Transfer frequency 

60 Hz 

Output current 

 100 mA 

Permitted inductive load 

< 200 mH 

Permitted capacitive load 

< 20 µF 

Short-circuit protection 

yes 

In Zone Signal 

yes 

 

 
 
 
 

Summary of Contents for BIC 1I22-P2A02-M18MN2-EPX07-050

Page 1: ...BIC 1I22 P2A02 M18MN2 EPX07 050 BIC 2I22 P2A02 M18MF2 EPX07 050 User s Guide...

Page 2: ...dicators 4 3 Installation 5 3 1 Transmission distance 5 3 2 Mutual interference 5 3 3 Installation in metal 5 3 4 Offset 5 3 5 Angular offset 6 3 6 Startup 6 3 7 InZone output 6 4 Technical Data 7 4 1...

Page 3: ...oid by damage from Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this User s Guide Obligations of the owner operator The device is a piece o...

Page 4: ...y the BIC system may pose a health hazard to persons with medical aids such as a pacemaker The minimum distance for this group of persons is 15 mm The operator is responsible for this minimum distance...

Page 5: ...protected brass enclosure Sensors For the standard version of electronic sensors observe the following Be sure that the total current draw of the sensors is not greater than 100mA Only use sensors wit...

Page 6: ...to be heated Install the components so that no metallic objects can collect on the coil cap When installing in metal the specified minimum distances from the surrounding sides of the metallic object m...

Page 7: ...Remote and sensors is complete For safety considerations the components must always be installed with power off The BIC system is designed so that a polarity reversal of the supply voltage on the Base...

Page 8: ...Housing degree of protection IP 67 Pigtail Cable PUR 7x0 342 Dimensions D x L in mm without pigtail M18 x 94 Weight 350 g Tightening torque 70 Nm Electrical data Operating voltage 24 V DC 10 Current...

Page 9: ...er D 4 5 mm Bending radius fixed cable 5 x D Bending radius repeated 10 x D Cable jacket material PUR Operating conditions Transmission distance 1 3 mm Operating temperature Ta Storage temperature 0 C...

Page 10: ...Sensing surface material PA 66 Housing degree of protection IP 67 Weight 310 g Dimensions D x L in mm without pigtail M18 x 61 Pigtail Cable PUR 7x0 342 Electrical data Operating voltage 12 V DC 10 No...

Page 11: ...Bending radius fixed cable 5xD Bending radius repeated 10xD Cable jacket material PUR Operating conditions Transmission distance 1 3 mm Operating temperature Ta Storage temperature 0 C 50 C 10 C 70 C...

Page 12: ...www balluff com 11 5 Appendix 5 1 Ordering information Product name Order code BIC 1I22 P2A02 M18MN2 EPX07 050 Base BIC007T BIC 2I22 P2A02 M18MF2 EPX07 050 Remote BIC007U...

Page 13: ...Balluff Inductive Coupler BIC 1I22 P2A02 M18MN2 EPX07 050 Base BIC 2I22 P2A02 M18MF2 EPX07 050 Remote www balluff com 12 Notes...

Page 14: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 937820 EN Edition K17 subject to modification...

Reviews: