background image

 

   www.balluff.com 

   

 

 

Safety 

1.1  Installation and 

startup 

 

Attention! 

Installation and startup are to be performed by trained technical personnel only. 
Skilled specialists are people who are familiar with the work such as installation 
and the operation of the product and have the necessary qualifications for these 
tasks. Any damage resulting from unauthorized tampering or improper use shall 
void warranty and liability claims against the manufacturer. The operator is 
responsible for ensuring that the valid safety and accident prevention regulations 
are observed in specific individual cases. 

 

1.2  General safety 

notes 

 

Commissioning and inspection 

The operating company shall be responsible for observance of locally applicable safety 
regulations. 
Before commissioning, carefully read the User's Guide. 
The system must not be used in applications in which the safety of persons depends on the 
function of the device. 

Intended use 

Warranty and liability claims against the manufacturer shall be rendered void by damage 
from: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this User's 
Guide. 

Obligations of the owner/operator! 

The device is a piece of equipment in accordance with EMC Class A. Such equipment may 
generate RF noise. The owner/operator must take appropriate precautionary measures 
against this for its use. The device may be used only with a power supply approved for this. 
Only approved cables may be connected. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 

 

 

Dangerous 
voltage 

 

Attention! 

Before working on the device, switch off its power supply. 

 

 

Intended use 

 

Attention! 

Inductive coupling systems (BIC) are devices for contact-free energy and signal 
transmission in industrial environments. 
 
Use is particularly not allowed: 

 

In environments with explosive atmospheres, 

 

in application in which the safety of  
people or machines can be affected by transmitted signals.  
(Safety-related circuits). 

 

1.3  Safety notes 

 

 

Caution! 

Metallic objects must not get in Zone A, B or between the sensing surfaces of the 
Base and Remote. Fire hazard! 

 

 
 

Summary of Contents for BIC 1I22-P2A02-M18MN2-EPX07-050

Page 1: ...BIC 1I22 P2A02 M18MN2 EPX07 050 BIC 2I22 P2A02 M18MF2 EPX07 050 User s Guide...

Page 2: ...dicators 4 3 Installation 5 3 1 Transmission distance 5 3 2 Mutual interference 5 3 3 Installation in metal 5 3 4 Offset 5 3 5 Angular offset 6 3 6 Startup 6 3 7 InZone output 6 4 Technical Data 7 4 1...

Page 3: ...oid by damage from Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this User s Guide Obligations of the owner operator The device is a piece o...

Page 4: ...y the BIC system may pose a health hazard to persons with medical aids such as a pacemaker The minimum distance for this group of persons is 15 mm The operator is responsible for this minimum distance...

Page 5: ...protected brass enclosure Sensors For the standard version of electronic sensors observe the following Be sure that the total current draw of the sensors is not greater than 100mA Only use sensors wit...

Page 6: ...to be heated Install the components so that no metallic objects can collect on the coil cap When installing in metal the specified minimum distances from the surrounding sides of the metallic object m...

Page 7: ...Remote and sensors is complete For safety considerations the components must always be installed with power off The BIC system is designed so that a polarity reversal of the supply voltage on the Base...

Page 8: ...Housing degree of protection IP 67 Pigtail Cable PUR 7x0 342 Dimensions D x L in mm without pigtail M18 x 94 Weight 350 g Tightening torque 70 Nm Electrical data Operating voltage 24 V DC 10 Current...

Page 9: ...er D 4 5 mm Bending radius fixed cable 5 x D Bending radius repeated 10 x D Cable jacket material PUR Operating conditions Transmission distance 1 3 mm Operating temperature Ta Storage temperature 0 C...

Page 10: ...Sensing surface material PA 66 Housing degree of protection IP 67 Weight 310 g Dimensions D x L in mm without pigtail M18 x 61 Pigtail Cable PUR 7x0 342 Electrical data Operating voltage 12 V DC 10 No...

Page 11: ...Bending radius fixed cable 5xD Bending radius repeated 10xD Cable jacket material PUR Operating conditions Transmission distance 1 3 mm Operating temperature Ta Storage temperature 0 C 50 C 10 C 70 C...

Page 12: ...www balluff com 11 5 Appendix 5 1 Ordering information Product name Order code BIC 1I22 P2A02 M18MN2 EPX07 050 Base BIC007T BIC 2I22 P2A02 M18MF2 EPX07 050 Remote BIC007U...

Page 13: ...Balluff Inductive Coupler BIC 1I22 P2A02 M18MN2 EPX07 050 Base BIC 2I22 P2A02 M18MF2 EPX07 050 Remote www balluff com 12 Notes...

Page 14: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 937820 EN Edition K17 subject to modification...

Reviews: