Safety 

 

Installation and 
Commissioning 

 

Attention! 

Installation and startup shall be performed by trained technical personnel only. 
Skilled specialists are people who are familiar with the work such as installation 
and the operation of the product and have the necessary qualifications for these 
tasks. Damage due to unauthorized tampering or improper use shall render the 
warranty and liability claims towards the manufacturer invalid. The user is 
responsible for ensuring compliance with safety and accident prevention 
regulations applicable in specific cases. 

 

 

General Safety 
Notes

 

 

Commissioning and Inspection 

The user assumes responsibility for compliance with applicable local safety regulations. 
The user guide must be read carefully before commissioning. 
The system may not be used in applications where personal safety is dependent upon 
device function. 

Intended Use 

Warranty and liability claims towards the manufacturer are rendered invalid by damages due 
to: 

 

unauthorized tampering 

 

improper use 

 

use, installation, handling contrary to the regulations in this user guide. 

User Responsibilities! 

This equipment is an AMV Class A device. Such devices can cause radio interference. The 
user must take appropriate precautionary measures for use. The device may only be 
operated with a specifically permitted power supply. Only permitted wiring may be 
connected. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 

 

 

Dangerous 
Voltage 

 

Attention! 

Before working on the device, switch off its power supply. 

 

 

Proper Use 

 

Attention! 

Inductive coupling systems (BIC) are devices for contact-free energy and signal 
transmission in industrial environments. 
 
Use is particularly not allowed: 

 

in explosive environments, 

 

in applications in which the safety of 
people or machines can be affected by transmitted signals (safety-related 
circuits). 

 

 

Safety Notes 

 

 

Caution! 

Metal objects may not cross Zones A, B, C or between active 
base and remote surfaces. 

Fire Hazard!

 

 

 
 

Summary of Contents for BIC 1I12-P2A25-M30MI1-BPX05-110

Page 1: ...BIC 1I12 P2A25 M30MI1 BPX05 110 BIC 2I12 P2A25 M30MI1 BPX03 010 User s Guide...

Page 2: ...iew 4 Topology 4 Block Diagram 4 Base Display 4 Timing Diagram 5 3 Installation 6 Transmission Distance 6 Mutual Interference 6 Offset 6 Installation in Metal 6 Angular Offset 7 Commissioning 7 InZone...

Page 3: ...manufacturer are rendered invalid by damages due to unauthorized tampering improper use use installation handling contrary to the regulations in this user guide User Responsibilities This equipment is...

Page 4: ...by the BIC system may pose a health hazard to persons with medical aids such as a pacemaker The minimum distance for such persons is 15 mm The operator is responsible for ensuring that this minimum d...

Page 5: ...se and Remote The inductive coupling between Base and Remote is displayed via the signal In Zone at the LED The signal In Zone will be transmitted to the control unit The inductive coupler system has...

Page 6: ...Diagram REMOTE Switch S S closed S open BASE DataValid BASE Signal t t rotate DAV trotate depends on the rotating speed Customer s specification maximum rotating speed of 44 rpm and mounting position...

Page 7: ...s must be observed to avoid mutual influence between neighboring base and remote A mm 40 mm Offset Permitted distances axial offset X mm Y mm 3 10 Installation in Metal Attention Device damage due to...

Page 8: ...y with remote coupler BIC 2I12 P2A25 M30MI1 BPX03 010 Commissioning is only possible after complete assembly of an entire transmission chain between base and remote For safety reasons components must...

Page 9: ...00 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operating voltage 24 V 10 Current drain max 300 mA No load current max 100 mA Overload pr...

Page 10: ...60 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operational 2 5 ms Switching frequency max 40 Hz Short circuit protection Yes No of digit...

Page 11: ...2A25 M30MI1 BPX05 110 Base BIC 2I12 P2A25 M30MI1 BPX03 010 Remote www balluff com 10 5 Attachment Ordering Information Product Name Item Number BIC 1I12 P2A25 M30MI1 BPX05 110 Base BIC007Z BIC 2I12 P2...

Page 12: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939250 726 EN 02 130491 Edition K20 Replaces Edition D18 Subjec...

Reviews: