background image

Balluff Inductive Coupler 
BIC 1I12-P2A25-M30MI1-BPX05-110 (Base) 
BIC 2I12-P2A25-M30MI1-BPX03-010 (Remote) 

www.balluff.com  

            

 

Technical Data 

  Base 

 

 

 

 

LED 

 

LED 

Display 

Function 

green 

static 

Connection established 

slowly flashing 

Power on, no remote found 

rapidly flashing 

Overload/short-circuit 

 

 

 

Mechanical 
Data 

  Housing material 

Stainless steel (1.4305) 

Sensing surface material 

PA66 

Housing degree of protection 

IP 67 

Dimensions (d x l in mm) 

M30 x 82.5 mm 

Thread pitch 

M30 x 1.5 mm 

Weight (with cable) 

120 g (600 g) 

Operating temperature 

-

40°C … 50°C 

Storage temperature 

-

40°C … 70°C 

Installation type 

Not flush 

 

 

Electrical Data 

 

Operating voltage  

24 V ± 10% 

Current drain  

max. 300 mA 

No-load current  

max. 100 mA 

Overload protection  

Yes  

Short-circuit protection  

Yes  

Polarity reversal protection  

Yes  

Number of digital outputs  

2 x PNP + DAV 

max. current load for outputs 

50 mA 

Operational readiness  

10 ms 

Transmission frequency 

max. 40 Hz 

Cable type  

PUR, 4 wire 2 x 0.75 + 2 x 0.14 shielded 

Cable length  

11 m 

Cable diameter D  

5.6 mm 

Least bending radius  

10 x D 

 

 

Terminal 
Assignment 

 

Color 

Signal 

Signal Type 

brown 

+ 24 V 

Power IN 

white 

GND 

Power RTN 

green 

Data valid 

Digital OUT 0/24 V 

yellow 

Signal 

Digital OUT 0/24 V 

blue 

Shield 

 

 

Summary of Contents for BIC 1I12-P2A25-M30MI1-BPX05-110

Page 1: ...BIC 1I12 P2A25 M30MI1 BPX05 110 BIC 2I12 P2A25 M30MI1 BPX03 010 User s Guide...

Page 2: ...iew 4 Topology 4 Block Diagram 4 Base Display 4 Timing Diagram 5 3 Installation 6 Transmission Distance 6 Mutual Interference 6 Offset 6 Installation in Metal 6 Angular Offset 7 Commissioning 7 InZone...

Page 3: ...manufacturer are rendered invalid by damages due to unauthorized tampering improper use use installation handling contrary to the regulations in this user guide User Responsibilities This equipment is...

Page 4: ...by the BIC system may pose a health hazard to persons with medical aids such as a pacemaker The minimum distance for such persons is 15 mm The operator is responsible for ensuring that this minimum d...

Page 5: ...se and Remote The inductive coupling between Base and Remote is displayed via the signal In Zone at the LED The signal In Zone will be transmitted to the control unit The inductive coupler system has...

Page 6: ...Diagram REMOTE Switch S S closed S open BASE DataValid BASE Signal t t rotate DAV trotate depends on the rotating speed Customer s specification maximum rotating speed of 44 rpm and mounting position...

Page 7: ...s must be observed to avoid mutual influence between neighboring base and remote A mm 40 mm Offset Permitted distances axial offset X mm Y mm 3 10 Installation in Metal Attention Device damage due to...

Page 8: ...y with remote coupler BIC 2I12 P2A25 M30MI1 BPX03 010 Commissioning is only possible after complete assembly of an entire transmission chain between base and remote For safety reasons components must...

Page 9: ...00 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operating voltage 24 V 10 Current drain max 300 mA No load current max 100 mA Overload pr...

Page 10: ...60 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operational 2 5 ms Switching frequency max 40 Hz Short circuit protection Yes No of digit...

Page 11: ...2A25 M30MI1 BPX05 110 Base BIC 2I12 P2A25 M30MI1 BPX03 010 Remote www balluff com 10 5 Attachment Ordering Information Product Name Item Number BIC 1I12 P2A25 M30MI1 BPX05 110 Base BIC007Z BIC 2I12 P2...

Page 12: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939250 726 EN 02 130491 Edition K20 Replaces Edition D18 Subjec...

Reviews: