background image

Balluff Inductive Coupler  
Base BIC 1I0-I2A50-M30MI3-SM4A4A and  
Remote BIC 2I0-I2A50-M30MI3-SM4A5A 
 

www.balluff.com   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and Connection 

5.3 

Angular offset 

  The permissible angular offset ensures proper function, even in difficult installation 

conditions: 

 
 

Distance D (mm) 

Angle X 

18° 

12° 

10° 

5° 

0° 

 

 

5.4 

Connection 

 

 

Caution! 

Device damage due to incorrect voltage supply! 
Malfunctions may occur if the ripple is too high or if the output voltage is not 
regulated. 

Use only approved, regulated voltage supplies 

 

Caution! 

The remote (receiver) may be damaged by voltage spikes if cables that are too 
long are used! To satisfy the EMC requirements, the cables must not be longer 
than 20 meters. 

 

 

5.5 

Series 
connection

 

  Two BIC systems can be connected in series. 

 

Caution! 

This cuts the power in half from 500 mA to 250 mA. The cable length between 
the individual components in each case must not be larger than 20 m. An 
angular offset can no longer be guaranteed. For that reason, the systems 
should be positioned accurately. It is not possible to have an air gap larger than 
5mm. 

 

 

No. 

Legend for graphic: 

Balluff components 

Profibus controller 

-  

Balluff power supply 

BAE PS-XA-1W-24-050-003 

Balluff IO-Link master 

BNI PBS-502-001-Z001 

4+5 

BIC IO-Link system 

BIC 1I0-I2A50-M30MI3-SM4A4A 
BIC 2I0-I2A50-M30MI3-SM4A5A 

Balluff sensor hub 

BNI IOL-104-000-K006 

Balluff sensor hub alternative to 6 

BNI IOL-104-000-K021 

 

Summary of Contents for BIC 1I0-I2A50-M30MI3-SM4A4A

Page 1: ...BIC IO Link unidirectional 500 mA IP67 User s Guide English...

Page 2: ...and diagnosis 5 4 1 Base indicators 5 4 2 Remote indicators 5 5 Installation and Connection 6 5 1 Mutual Interference 6 5 2 Installation in metal 6 5 3 Angular offset 7 5 4 Connection 7 5 5 Series co...

Page 3: ...ollowing typographical conventions are used in this guide Enumerations Enumerations are shown as a list with an en dash Entry 1 Entry 2 Syntax Numbers Decimal numbers are shown without additional indi...

Page 4: ...ed the device must be taken out of operation and protected against unauthorized use 2 5 Meaning of the warning notes The warning notices in this guide and the measures described for avoiding dangers m...

Page 5: ...ansmitted from the remote to the base The energy available for the IO Link device is dependent on the distance and on the offset between base and remote and is therefore limited For this reason the to...

Page 6: ...nk communication between master and base is OK Red flashing No remote detected Red off Remote present IO Link communication OK Red static Remote present no IO Link communication to connected device 4...

Page 7: ...SM4A4A 100 BIC 2I0 I2A50 M30MI3 SM4A5A 100 5 2 Installation in metal Caution Device damage due to induction effects Metallic objects on the coil cap cause the objects to be heated Install the compone...

Page 8: ...g are used To satisfy the EMC requirements the cables must not be longer than 20 meters 5 5 Series connection Two BIC systems can be connected in series Caution This cuts the power in half from 500 mA...

Page 9: ...orque 70 Nm 6 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C EMC EN 61000 4 2 3 4 5 6 EN 55011 Severity 4 3 4B 2 3 S...

Page 10: ...160 g Tightening torque 70 Nm 7 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C EMC EN 61000 4 2 3 4 5 6 EN 55011 Se...

Page 11: ...it 2 PD Byte 0 Bit 1 PD Byte 0 Bit 0 Byte 1 7 6 5 4 3 2 1 0 PD Byte 1 Bit 7 PD Byte 1 Bit 6 PD Byte 1 Bit 5 PD Byte 1 Bit 4 PD Byte 1 Bit 3 PD Byte 1 Bit 2 PD Byte 1 Bit 1 PD Byte 1 Bit 0 Byte 2 7 6 5...

Page 12: ...x 0B 0 x 10 0 Vendor name 7 bytes BALLUFF 0 x 11 0 Vendor text 15 bytes www balluff com 0 x 12 0 Product name 37 bytes BIC 1I0 I2A50 M30MI3 SM4A4A 0 x 13 0 Product ID 7 bytes BIC000C 0 x 14 0 Product...

Page 13: ...mper BCC M415 M414 3A 304 PX0434 xxx XXX cable length PUR for remote open cable end BCC M415 0000 1A 003 PX0434 xxx XXX cable length 9 2 Installation accessories Description Description Fig BES 30 0 B...

Page 14: ...uff Inductive Coupler Base 1 Remote 2 Technology PNP variant 24 V power class 500 mA I2 4 bytes Housing shape M30x1 5 Housing material M brass and length SM4A5A Connector M12 axial Number of pins and...

Page 15: ...E Edition L14 Replaces Edition C12 Subject to modification Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de www balluff com www ballu...