Balluff Inductive Coupler
Base BIC 1I0-I2A50-M30MI3-SM4A4A and
Remote BIC 2I0-I2A50-M30MI3-SM4A5A
www.balluff.com
7
5
Installation and Connection
5.3
Angular offset
The permissible angular offset ensures proper function, even in difficult installation
conditions:
Distance D (mm)
Angle X
1
18°
2
12°
3
10°
4
5°
5
0°
5.4
Connection
Caution!
Device damage due to incorrect voltage supply!
Malfunctions may occur if the ripple is too high or if the output voltage is not
regulated.
Use only approved, regulated voltage supplies
Caution!
The remote (receiver) may be damaged by voltage spikes if cables that are too
long are used! To satisfy the EMC requirements, the cables must not be longer
than 20 meters.
5.5
Series
connection
Two BIC systems can be connected in series.
Caution!
This cuts the power in half from 500 mA to 250 mA. The cable length between
the individual components in each case must not be larger than 20 m. An
angular offset can no longer be guaranteed. For that reason, the systems
should be positioned accurately. It is not possible to have an air gap larger than
5mm.
No.
Legend for graphic:
Balluff components
1
Profibus controller
-
2
Balluff power supply
BAE PS-XA-1W-24-050-003
3
Balluff IO-Link master
BNI PBS-502-001-Z001
4+5
BIC IO-Link system
BIC 1I0-I2A50-M30MI3-SM4A4A
BIC 2I0-I2A50-M30MI3-SM4A5A
6
Balluff sensor hub
BNI IOL-104-000-K006
7
Balluff sensor hub alternative to 6
BNI IOL-104-000-K021