Balluff Inductive Coupler
Base BIC 1I0-I2A50-M30MI3-SM4A4A and
Remote BIC 2I0-I2A50-M30MI3-SM4A5A
8
IO-Link communication
8.1
Process data
The "Base" transmits 4 bytes of input via the IO-Link. The first ten represent the data of
the IO-Link device connected to the "Remote", while the 4th byte contains status
information. If an IO-Link device that outputs less than 4 bytes of input data is connected
to the "Remote", the remaining, unused bytes are transmitted with "0".
Byte 0
7
6
5
4
3
2
1
0
PD By
te
0
Bi
t
7
PD By
te
0
Bi
t
6
PD By
te
0
Bi
t
5
PD By
te
0
Bi
t
4
PD By
te
0
Bi
t
3
PD By
te
0
Bi
t
2
PD By
te
0
Bi
t
1
PD By
te
0
Bi
t
0
Byte 1*
7
6
5
4
3
2
1
0
PD By
te
1
Bi
t
7
PD By
te
1
Bi
t
6
PD By
te
1
Bi
t
5
PD By
te
1
Bi
t
4
PD By
te
1
Bi
t
3
PD By
te
1
Bi
t
2
PD By
te
1
Bi
t
1
PD By
te
1
Bi
t
0
Byte 2*
7
6
5
4
3
2
1
0
PD By
te
2
Bi
t
7
PD By
te
2
Bi
t
6
PD By
te
2
Bi
t
5
PD By
te
2
Bi
t
4
PD By
te
2
Bi
t
3
PD By
te
2
Bi
t
2
PD By
te
2
Bi
t
1
PD By
te
2
Bi
t
0
Byte 3
7
6
5
4
3
2
1
0
n
o
t
u
s
e
d
n
o
t
u
s
e
d
n
o
t
u
s
e
d
n
o
t
u
s
e
d
Sta
tu
s
„Su
p
p
ly
Re
m
o
te
“
Sta
tu
s
„Sh
o
rt
Re
m
o
te
“
Sta
tu
s
“n
zo
ne
”
Sta
tu
s
“Com
”
* All unused bits and bytes are output with "0".
Explanation of the status bits
Status
Meaning
"Supply remote"
Voltage at the remote is less than 18V
"Short remote"
Short-circuit at the IO-Link interface of the remote
“Inzone”
No remote detected
“Com”
No IO-Link device detected
Note, tip
Process data update time is max. 50ms