Balluff Inductive Coupler
Base BIC 1I0-I2A50-M30MI3-SM4A4A and
Remote BIC 2I0-I2A50-M30MI3-SM4A5A
5
Installation and Connection
5.1
Mutual
Interference
Caution!
Improper mounting may affect the function of the system and lead to damage.
The spacings specified for installation must be adhered to.
To prevent mutual interference with adjacent bases or remotes, the specified minimum
distances must be adhered to:
Type
A (mm)
BIC 1I0-I2A50-M30MI3-SM4A4A
100
BIC 2I0-I2A50-M30MI3-SM4A5A
100
5.2
Installation in
metal
Caution!
Device damage due to induction effects
Metallic objects on the coil cap cause the objects to be heated.
Install the components so that no metallic objects can collect on the coil cap.
There is a fire hazard!
When installing in metal, the specified minimum distances to the surrounding sides of the
metallic object must be maintained. Otherwise, the transmission distance between
transmitter and receiver changes.
The transmission distance can also be influenced by the type of metal.
Type
A (mm)
B (mm)
BIC 1I0-I2A50-M30MI3-SM4A4A
30
20
BIC 2I0-I2A50-M30MI3-SM4A5A
30
20