Trouble shooting
Scope of delivery, transportation and disposal
• Inspect packaging and content for damage.
• Check the delivery for completeness.
• Disposal note: Do not dispose the device in the domestic waste, comply with relevant laws and
national regulations.
List of applicable standards
CAN/CSA-C22.2 No. 60947-5-2-14
CAN/CSA-C22.2 No. 60079-0:15
CAN/CSA-C22.2 No. 60079-11:14
UL 60947-5-2 Third Edition
ANSI/UL 60079-0:13
ANSI/UL 60079-11:13
Failure
Cause of failure
Remedy
The functioning indicator does not light
up in the electronic evaluation devices
when the proximity switch is actuated
Supply voltage too low or
not connected
Check power supply
The display “CHK” lights up in the
electronic evaluation devices
cable break or short circuit of
the connetion-cable
Check the connection-cable
No change of
switching signal
Operation of the proximity
switch outside of specification
Check range of application
of the proximity switch