background image

BN

BU

+

+

Supply voltage

Relay output

BAE SA-XE-

***-XR-SA39

hazardous area

intrinsically safe sensor

accord. to IEC 60947-5-6

non hazardous area

grounded metal frame

Type

max. torque

M12x1
M18x1
M30x1,5

10 Nm
25 Nm
40 Nm

52

35

M30x1,5

36

15

10

No 947390-726 EN ∙ 01.131212 ∙ E21;

Subject to modification. Replaces E20.

BA-S36101-GB-2021-18

Instruction manual BES M30EH2-GNX15F-BT02-X03

Page 3

Dimensions

Connection diagram

Installation

Colour code BK: black | BN: brown | BU: blue | GY: grey | WH: white

Summary of Contents for BES M30EH2-GNX15F-BT02-X03

Page 1: ...english User s guide fran ais Notice d utilisation BES M30EH2 GNX15F BT02 X03...

Page 2: ...nstallation provisions Absolutely abide by the specific conditions Installation and operation Make sure that the device is used only in the area of application corresponding to its Ex marking Do not m...

Page 3: ...Effective internal inductivity Li 1 2 mH Electrostatic chargeable plastic housing With reference to group II gas 573 mm With reference to group III dust 1421 mm Housing material AISI 316 Ti PTFE PVDF...

Page 4: ...rounded metal frame Type max torque M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm 52 35 M30x1 5 36 15 10 No 947390 726 EN 01 131212 E21 Subject to modification Replaces E20 BA S36101 GB 2021 18 Instruction ma...

Page 5: ...and national regulations List of applicable standards CAN CSA C22 2 No 60947 5 2 14 CAN CSA C22 2 No 60079 0 15 CAN CSA C22 2 No 60079 11 14 UL 60947 5 2 Third Edition ANSI UL 60079 0 13 ANSI UL 60079...

Page 6: ...articuli res Installation et mise en service S assurer que l appareil est utilis uniquement dans une zone correspondant son marquage Ex Ne pas proc der des modifications sur l appareil par exemple le...

Page 7: ...iques susceptibles d tre charg es d lectricit statique Consid ration conform ment au groupe II gaz 573 mm Consid ration conform ment au groupe III poussi re 1421 mm Mat riaux du bo tier acier inoxydab...

Page 8: ...sion cadre de montage m tallique mis la terre de mani re standard type couple de tension max M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm 52 35 M30x1 5 36 15 10 N 947390 726 FR 01 131212 E21 Sous r serve de...

Page 9: ...les prescriptions nationales Liste des normes applicables CAN CSA C22 2 No 60947 5 2 14 CAN CSA C22 2 No 60079 0 15 CAN CSA C22 2 No 60079 11 14 UL 60947 5 2 Third Edition ANSI UL 60079 0 13 ANSI UL 6...

Page 10: ...ngshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Phone 86 400 820 0016 Fax 86 400 920 2622 service cn balluff com cn DACH Service Center Germany Balluff GmbH Schur...

Reviews: