2.3 Release zone
The outputs (OSSDs) are only released when damping occurs in the
release zone. Outside this release zone the outputs remain off.
NOTICE
Improper damping elements
Changes or deviations in the release zone may occur.
►
Use only standardized targets which correspond to the standardized
target in shape and size.
Please refer to the following table for the assured turn-off distance
sar for the various sensors:
Order code
Turn-off distance
BES0574
> 6 mm
BES0575
> 12 mm
BES0576
> 7 mm
BES0578
> 22 mm
BES0579
> 15 mm
Release zone for selected materials
Material
Release zone1)
BES0574
BES0575
BES0576
BES0578
BES0579
FE360
(=ST37K)
0.5…4 mm 1…8 mm
1…5 mm
1…15 mm
1…10 mm
Stainless
steel 1.4301
(V2A)
0…3.1 mm 0…5.6 mm 0…3.5 mm 0…11.4 mm 0…7.4 mm
AIMg3G22
0…1.8 mm 0…3.2 mm 0…2 mm
0…6.8 mm
0…4.3 mm
CuZn37
0…2 mm
0…3.2 mm 0…2 mm
0…7.2 mm
0…4.6 mm
Cu
0…1.2 mm 0…2.4 mm 0…1.5 mm 0…5.5 mm
0…3.3 mm
www.balluff.com