7.CONTROL MODE
19
1. Energy-saving
4.1 Press the SOFT button on the remote controller to activate the energy-saving function. Now the
energy-saving symbol appears on the screen. Press the button again to cancel this function, the
corresponding symbol will go off.
4.2 During energy-saving mode, the electric current will be limited to 60% of the rating level through
adjusting the compressor revolving frequency and limiting the maximum current.
4.3 This mode cannot be cancelled by the switching-on and off operations. When the machine is
turned off, the energy-saving symbol will remain on.
2. Sleeping
5.1 During heating or cooling mode, press the SLEEP button on the remote controller, the sleeping
mode can be set or cancelled and the sleeping symbol on the screen will light up or go off
accordingly.
5.2 Heating: After this function is enable d, the setting temperature will fall down 3 degrees within an
hour. Two hours later, the temperature will fall down another 4 degrees, and the machine will be
turned off after running for another 5 hours.
5.3 Cooling: After this function is started, the setting temperature will rise 1 degree within an hour,
and the
machine will be turned off automatically after another 7 hours.
5.4 The default mode is sleeping off. The sleeping function will be cancelled after the machine is
switched off.
3. High-power
In this mode, the indoor fan speed will go into high level. The compressor runs at the max permissible
frequency, which will be displayed on the screen. The original running mode will be automatically
resumed after running for 15 minutes.
4. Temporary switch
7.1 If the remote controller is missing, press the temporary switch and the system starts in the
automatic mode, press the switch again to stop the system. Automatic mode follows:
A indoor temperature 26 cooling mode temperature setting 26
B indoor temperature 23 heating mode temperature setting 26
C 23 indoor temperature 26 fan mode
Indoor fan speed is automatic in automatic mode.
7.2 Hold down the temporary switch for 5 seconds or longer and the system is forced to run in the
cooling mode regardless of indoor temperature.
NOTE:
Operating frequency and rated values of the compressor:
Item
KFR-3601GW/BPE
KFR-4001GW/BPE
KFR-3502GW/BPE
Hz
Mode
Frequency
range
Rated
frequency
Frequency
range
Rated
frequency
Frequency
range
Rated
frequency
Cooling
30-110
84
30-110
94
15-110
82
Heating
30-137
96
30-137
112
15-137
92
°Ñ
°Ñ
°Ñ
°Ñ
°Ñ
°Ñ