HABFM-1401001
VERSION: 07_11
FLIGHT MANUAL
–
BALLONS CHAIZE
FLIGHT MANUAL
–
BALLONS CHAIZE
–
PAGE 40/64
Siège Social / Headquarters:
Chemin de Mirecouly - 07100 Annonay
| Atelier / Workshop:
188, avenue Ferdinand Janvier - 07100 Annonay - France
Atelier / Workshop - Tél. +33 (0)4 75 33 65 18 - Mobile - Tél. +33 (0)6 32 00 04 83 - [email protected] -
www.ballonschaize.com
SARL au capital de 20.00
0€
•
SIRET 790820062 0001
2 • TVA FR54 790820062 00012
•
If there are additional bottles, check them by successively connecting the primary circuits to
each one, and successively opening the valves controlling both circuits, then igniting the
corresponding burner.
➢
For each burner:
•
Close the spigot of the second bottle, of the master bottle, and any additional bottles.
•
Bleed the pipes by actuating both control valves;
•
Kill the pilot light by closing its supply spigot on the master bottle.
➢
Ground handling
•
In any case the basket should never be transported with the burner mounted.
IV.4.1
Placing the balloons on the take-off site
With the mouth to the wind, and the base of the basket near the edge of the site:
•
verify proper closing of the flight control valve in accordance with the guide numbers on
components marked with stickers;
•
ensure proper placing of:
•
the envelope and basket hangers on the load frame;
•
the parachute line;
•
the FDS (fast deflation system) control cord if it is present;
•
the vent cord if vents are present;
•
the connecting wires to the thermometer sensors if the balloon is fitted with them;
•
safety fuses at the balloon's inner apex.
•
If the door option is fitted, always lay the basket with the door closed and on the up side.