HABFM-1401001
VERSION: 07_9
FLIGHT MANUAL
–
BALLONS CHAIZE
FLIGHT MANUAL
–
BALLONS CHAIZE
–
PAGE 35/64
Siège Social / Headquarters:
Chemin de Mirecouly - 07100 Annonay
| Atelier / Workshop:
188, avenue Ferdinand Janvier - 07100 Annonay - France
Atelier / Workshop - Tél. +33 (0)4 75 33 65 18 - Mobile - Tél. +33 (0)6 32 00 04 83 - [email protected] -
www.ballonschaize.com
SARL au capital de 20.00
0€
•
SIRET 790820062 0001
2 • TVA FR54 790820062 00012
Land as soon as possible.
III.6.2
If one of the pilot lights are extinguished
Re-ignite it using matches or a lighter; these objects should always be kept on hand.
➢
In the event of an irrecoverable breakdown:
•
shut down the faulty pilot light's power supply.
•
If the burner is fitted with a silencer, open it slightly and use it as a pilot light.
➢
If the burner is not fitted with a silencer:
•
Close the fuel bottle
•
Open the burner valve wide
•
Allow a small amount of gas to escape by opening the valve 1/4 and then ignite it.
•
Open the valve 1/4 turn or all the way to use the burner.
•
Partially close the valve 1/4 of a turn to stop the heating.
•
Fly close to the ground and land as soon as possible.
III.6.3
Valve stuck (blocked) in open position.
Try moving the lever to the closed position. If the valve remains open, close the spigot of the
bottle that supplies the faulty burner. Switch over to the second circuit and land as soon as
possible.
III.7
Parachute line malfunction:
If the parachute line is stuck in a partially open position, immediately compensate the loss of hot air
by operating the heating system non-stop as required. Land as soon as possible.