HABFM-1401001
VERSION: 07_9
FLIGHT MANUAL
–
BALLONS CHAIZE
FLIGHT MANUAL
–
BALLONS CHAIZE
–
PAGE 37/64
Siège Social / Headquarters:
Chemin de Mirecouly - 07100 Annonay
| Atelier / Workshop:
188, avenue Ferdinand Janvier - 07100 Annonay - France
Atelier / Workshop - Tél. +33 (0)4 75 33 65 18 - Mobile - Tél. +33 (0)6 32 00 04 83 - [email protected] -
www.ballonschaize.com
SARL au capital de 20.00
0€
•
SIRET 790820062 0001
2 • TVA FR54 790820062 00012
time. When the passengers evacuate the balloon, it will be lighter: ensure that it does not take off
again.
If the balloon is hanging from the electric power line or electrical pylon, do not attempt to
evacuate; ensure that nobody (in the basket or on the ground) touches the metal parts of the
balloon. Wait for qualified rescue services to confirm that electrical power has been switched off.
III.12
Degradation of the envelope in flight:
Perform heating to replace hot air lost because of the damage; maintain a controlled descent rate.
Descend to low altitude and land as soon as possible.
If you are not able to control the descent rate, consider throwing overboard all items that can be
jettisoned, including non-essential fuel bottles; take care that there are no people directly below.
Ask the passengers to assume the fast landing position.