5-2 Troubleshooting and Maintenance
MN2488
Cleaning
Keeping the light tower clean is an important part of good operation. If dirt buildup is not
removed, the light tower will run hotter than normal and it’s life is reduced.
The following are general guidelines for cleaning.
1.
Clean the light tower and remove any and all dust, dirt, or other foreign material.
2.
Inspect and clean the cooling air intake and exhaust louvers of the enclosure. Make
sure they are clean. Remove dirt or any buildup that may restrict the cooling air flow.
3.
Clean the light tower and its components with a damp cloth or sponge.
Never use a water hose or pressure washer as this may damage electrical
components.
4.
Inspect and replace any control panel components that are broken or not working
properly (receptacles, circuit breakers, switches, etc.)
5.
Inspect and clean all engine linkages so they operate properly.
Maintenance Schedule
Maintenance Interval
Maintenance Operation
10 Hrs
(Daily)
50 Hrs. 125 Hrs. 250 Hrs. 500 Hrs.
1000
Hrs.
2500
Hrs.
Safety Guard Inspection
S
Fluid Leak Inspection
−
General
S
Oil Level Check
S
Coolant Level Check
S
Fan/Alternator Belt Inspection
S
Radiator Core Inspection
S
Air Filter Element Check (Dry Type)
Air Filter Check (Oil Bath Type)
S
Oil Replacement
−
Initial only
S
Oil Filter Replacement
−
Initial only
S
Oil Replacement
S
Check mast cables. Check lighting lead wires
S
Oil Filter Replacement
S
Fuel Filter Replacement
S
Coolant Hose Replacement
S
Fan/Alternator Belt Tension Adjustment
S
Valve Adjustment
S
Fan/Alternator Belt Replacement
S
Fuel Injection System Adjustments
S
Grease the mast collar grease fitting
S
Clean Fuel Tank
S
Grease trailer bearings
S
Coolant Replacement
S
Replace Timing Belt
S
Add fluid(s) as needed.
After inspection, adjust, repair or replace as needed.
Clean as often as needed.
Replace air filter if air flow is restricted or one (1) year.
Service oil bath filter element (upper and lower) as needed. Replace reservoir oil as needed.
Note: In dusty conditions, service the oil bath air filter every four (4) hours of operation.
See engine manufactures recommendation.
Replace coolant every 2500 hours or 2 years.
Summary of Contents for POW'R LITE PL6000K
Page 1: ...POW R LITE PL6000K Portable Light Tower Installation Operating Manual 9 06 MN2488 ...
Page 4: ...ii Table of Contents MN2488 ...
Page 12: ...2 2 General Information MN2488 ...
Page 17: ...Receiving Installation 3 5 MN2488 Figure 3 3 Trailer Harness ...
Page 18: ...3 6 Receiving Installation MN2488 ...
Page 30: ...5 4 Troubleshooting and Maintenance MN2488 Figure 5 7 Flood Light Mast Wiring ...
Page 31: ...Troubleshooting and Maintenance 5 5 MN2488 Figure 5 8 Engine and Control Wiring ...
Page 32: ...5 6 Troubleshooting and Maintenance MN2488 ...
Page 33: ...Baldor District Offices ...