www.supportme.net
Operation 5-7
MN1924
5. Click
Apply
.
This immediately sets the scaling factor for
the selected axis, which will remain in the
NextMove ESB until another scale is defined
or
power
is
removed
from
the
NextMove ESB. See section 5.10 for details
about saving configuration parameters.
5.3.2 Setting the drive enable output
A drive enable output allows NextMove ESB to enable the external amplifier to allow motion, or
disable it in the event of an error. Each axis can be configured with its own drive enable output,
or can share an output with other axes. If an output is shared, an error on any of the axes
sharing the output will cause all of them to be disabled.
The drive enable output can either be the relay or a digital output.
1. In the Toolbox, click the Digital I/O icon.
2. At the bottom of the Digital I/O screen, click
the
Digital Outputs
tab.
The left of the screen shows yellow High and
Low icons. These describe how the output
should behave when activated (to enable the
axis).
3. If you are going to use the relay, ignore this
step and go straight to step 4.
If you are going to use a digital output, drag
the appropriate yellow icon to the grey OUT
icon that will be used as the drive enable
output. In this example, OUT1 is being used.
The icon’s color will change to bright blue.
Summary of Contents for Nextmove ESB
Page 1: ...NextMove ESB Motion Controller MOTION CONTROL Installation Manual 1 04 MN1924...
Page 2: ......
Page 6: ...iv Contents MN1924...
Page 16: ...www supportme net 3 4 Basic Installation MN1924...
Page 42: ...www supportme net 4 26 Input Output MN1924...
Page 57: ...www supportme net Operation 5 15 MN1924 Figure 28 The NextMove ESB servo loop...
Page 88: ...www supportme net A 4 General MN1924...
Page 94: ...Index MN1924...
Page 96: ...Comments MN1924 Thank you for taking the time to help us...
Page 97: ......