5

3)  Pressing cal cycles through options 

4)  Pressing reset cycles through values for each option 

5)  Pressing and holding reset 5 seconds saves the set-

tings and returns to manual mode.

6)  Options are 

 

 

- Option 1 sleep y/n

 

- Option2 batch resets to zero on wake y/n 

Low Battery

The  battery  segment  will  flash  when  the  battery  is  low 

and needs replacing.

The  control  handle  will  not  operate  in  auto  mode  when 

the battery is low, although the gun can still be used in 

manual mode.

NOTE:

 

When the battery segment starts flashing replace 

the battery as soon as possible.

Battery Replacement

1)  Remove the protective boot.

2)  Remove the battery cover screw located near the inline 

(forward) outlet port and remove the battery cover.

3)  Replace the two AA Alkaline batteries. (Check + - are 

correct)

4)  Inspect the battery cover seal for damage and replace 

if necessary.

5)  Replace battery cover and tighten screw, while press-

ing cover in place.

Error Message

If an error is detected in meter operation, the following error 

codes will appear on the display.

Err1 – Sensor error

Err2 – Auto shut off failure

Err3 – Flow rate too high

Err4 – Calibration error

Err5 – Computer error

To reset the meter after an error message press 

reset

.

  Note:

 Lightly lubricate the valve cam before

  assembly.

B)  Place o-ring (19) onto valve cam (16).

  Note: 

The cutout section in the middle of the 

  valve cam (16) must face the inlet swivel (31).

C)  Replace the valve cam (16) into the body (15).

  Note the orientation shown on the assembly 

  drawing. Fit the second o-ring (19) and washer 

  (20).

D)  Slide lever assembly (34) into position and replace 

  the two allen screws (32). Use loctite or similar 

  sealant.

E)  Replace plunger (24).

 

Note:

 The end hole in the plunger must face the 

  meter.

F)  Assemble the seal/valve body (25, 26) and 

  spring (27) and replace into the handle body.

  Note:

 Install the spring, small end first.

G)  Replace handle sleeve (28).

H)  Replace washer (29), o-ring (25), and swivel 

  assembly (31) and screw firmly into place. Use 

  Loctite or similar sealant.

 

Pressure Relief Procedure:

Follow this procedure whenever you shut off 

the pump, when checking or servicing any part 

of the system and when installing, cleaning or 

changing any part of the system.

1)   Disconnect the air to the pump.

2)   Point dispensing valve away from

 

yourself and others.

3)   Open dispensing valve until

 

pressure is relieved.

WARNING

!

Maintenance

Inspect your control handle daily for any signs of 

damage. Replace any damaged parts or components as 

required.

Handle Disassembly

Use a clean work area to carry out maintenance. 

A)  Remove the fluid hose from the control handle 

  inlet swivel (31).

B)  Unscrew and remove swivel (31), washer (29), 

  and o-ring (30) from the control handle inlet. 

  Clean or replace the strainer and o-ring. 

  CAUTION:  The swivel is under spring   

 

  tension.

C)  Slide off the handle sleeve (28).

D)  Remove valve spring (27), seal/valve body  

 

  assembly (25,26) and plunger (24).

Lever and Valve Removal

A)  Using a 2.5mm allen wrench, remove the two 

  handle screws (32).

B)  Remove lever (34).

C)  Remove the washer (20) and o-ring (19), then 

  push the valve cam (16) from the handle body 
  (15), and remove o-ring (19).

Handle Reassembly

A)  Clean and inspect all parts. Replace any  suspect,  

  worn, or damaged components.

Meter Disassembly

A)  Unscrew the swivel assembly (31) two complete    

 

turns to allow easy disassembly and reassembly of  

 

the meter and remove boot (1).

B)  Remove battery cover screw (5) and batteries (9).

C)  Remove the three screws (11) and the calibration   

 

port screw (18) from the underside of the meter.

D)  Carefully remove the computer module (2) from the  

 

module housing (10).

  Note:

 The computer module is non repairable  

 

 

and will need to be replaced if damaged.

E)  Remove the four allen screws (17) from the  

 

 

underside of the meter and remove the module    

 

housing (10).

Summary of Contents for 3331-014

Page 1: ...g or servicing this equipment OPERATION INSTALLATION MAINTENANCE AND REPAIR GUIDE SERVICE BULLETIN SB3021 Rev H 10 08 P SET ELECTRONIC PRESET CONTROL HANDLE Model 3331 014 with Semi Automatic Tip Mode...

Page 2: ...of this control handle doing so may cause damage to the control handle and or personal injury Under no circumstances should the dispensing valve be aimed at any person at any time Personal injury may...

Page 3: ...he handle press the lever push the button and then release the lever To release the latch in manual or automatic mode simply press and release the lever When the control handle is in automatic mode th...

Page 4: ...Stop at the preset volume to be changed C To change the preset volumes press the 10 1 or 0 1 buttons to obtain the desired volume D Press and hold the auto button for approximately 5 seconds to store...

Page 5: ...27 and replace into the handle body Note Install the spring small end first G Replace handle sleeve 28 H Replace washer 29 o ring 25 and swivel assembly 31 and screw firmly into place Use Loctite or...

Page 6: ...e t u p m o c s g n i r o d e g a m a D s g n i r o d e g a m a d e c a l p e R e t a r w o l f w o L r e n i a r t s d e k c o l B r e n i a r t s e c a l p e R t e l n i l e v i w s e h t m o r f g...

Page 7: ...se Assembly 24 1 Plunger 5 1 Battery Cover Screw 25 1 Seal 6 1 O Ring 26 1 Valve Body 7 1 Battery Cover 27 1 Valve Spring 8 1 O Ring 28 1 Handle Sleeve 9 2 AA Alkaline Batteries 29 1 Washer 10 1 Modul...

Page 8: ...ing Balcrank Lubrication Equipment Direct Service Warranty Procedure Eligible products are defined in the Balcrank Lubrication Equipment Accessories User Price List Refer to the Balcrank web site www...