5
Model
A
B
C
D
Weight
1150-022 24.02”
7.87”
1.02” 16.14”
7.32 lb
1150-023 36.42”
7.87”
1.02” 28.54”
9.48 lb
1150-024 44.09”
7.87”
1.02” 36.22” 10.58 lb
DIMENSIONS
INSTALLATION
These pumps must be mounted on drums
using covers fitted with a 2” bung. Loosen the
star nut (1) of the bung adapter to remove
the inferior nut (3), and screw this into the 2”
bung opening of the cover. Place the star nut
(1) and the three jaws (2) on the suction tube.
Insert the pump through the opening and
fasten the assembly at the desired height (fig
2). Fasten the cover to the drum.
Fig. 2
See figure 3 for a typical installation with all
the recommended accessories for the pump to
operate correctly.
NOTE:
The compressed air supply must be
between 40 and 140 psi (2.8 – 10 bar), 90 psi
(6 bar) being the recommended pressure. An
air shut-off valve must be installed, in order to
be able to close the compressed air line at the
end of the day.
WARNING
!
If the system is left unattended and the
air inlet is not closed, if there is a leak-
age at some point of the grease outlet
circuit, the pump will start automatically,
emptying the container.
NOTE
!
The compressed air supply must be
between 40 and 140 psi (2.8 – 10 bar), 90
psi (6 bar) being the recommended pres-
sure. An air shut-off valve must be installed,
in order to be able to close the compressed
air line at the end of the day.