40940_N
02-08-19
10
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370,
6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and
domestic applied for and pending. All material copyright of Balboa Water Group.
Adjusting Filtration
Sets Filter 1 length in hours
Sets start hour
Selects minutes
Selects part of an hour
SET
FLTR1
P
SET
FLTR1
P
SET
FLTR1 P
Sets 15-minute increments
SET
FLTR1 P
FLTR1
FLTR1
SET
FLTR1
SET
FLTR1
SET
FLTR1
Shows/flashes start time
FLTR1
Sub-Menu Detail – Set Filter Cycle 1
to show RUN HRS
to show F1 ENDS xx:xx
Sets 15-minute increments
A
1
While the Temperature is
still flashing, press Light
repeatedly until FLTR 1
appears in the LCD.
SET
RANGE
Main Screen
READY
RANGE FLTR1
Main Screen
READY
RANGE FLTR1
Sets Filter 1 length in hours
Sets start hour
Selects minutes
Selects part of an hour
SET
FLTR 2
P
SET
FLTR 2
P
SET
FLTR 2 P
Sets 15-minute increments
SET
FLTR 2 P
FLTR 2
FLTR 2
SET
FLTR 2
SET
FLTR 2
SET
FLTR 2
Shows/flashes start time
FLTR 2
to show RUN HRS
to show F1 ENDS xx:xx
Sets 15-minute increments
A
Main Screen
READY
RANGE FLTR1
2
To next item in
Main Menu
Main Screen
READY
RANGE FLTR1
SET
FLTR 2
SET
FLTR 2
To Set
To Set
To Set
To Set
To Set
Waiting
a few seconds
reverts to original setting
Waiting
a few seconds
reverts to original setting
Wait to
Revert
*****
Waiting
a few seconds
reverts to original setting
*****
Waiting a few seconds
will lose any new Filter 1
Start Time and Run Hours and
revert to the previous Filter 1 settings.
*****
To Set
Waiting a few seconds
will lose any new Filter 2 On/OFF,
Start Time and Run Hours and
revert to any previous Filter 2 settings.
*****
*****
Wait to
Revert
*****
*****
Main Filtration
Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of
the display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calcu-
lates the end time and displays it automatically.
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
*****
Filter Cycle 2 - Optional Filtration
Filter Cycle 2 is OFF by default.
It is possible to overlap Filter Cycle 1 and Filter
Cycle 2, which will shorten overall filtration by the
overlap amount.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/
or a Blower will purge water from their respective plumbing by
running briefly at the beginning of each filter cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will
initiate a purge when Filter Cycle 2 is programmed to begin.