background image

40940_N

02-08-19

8

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 

6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and 

domestic applied for and pending.   All material copyright of Balboa Water Group.

Restricting Operation

Sub-Menu Detail – Locking the Set Temperature or All Buttons

LOCK will remain on the display 

for 3 seconds and then revert to the normal display.

When the Temperature is locked, the panel will display the Set Temperature

by pressing a Temperature Button, as ususal. 

LOCK will appear if an attempt to reset the temperature is made with a subsequent button press.

Adjustable settings in the menus are also locked.

Other function buttons will operate normally.

Panel Locked

Temperature Locked

Any 

Button 

Press

Locks all function buttons.

Locks Temp. and Settings.

SET

SET

SET

SET

READY

RANGE FLTR1

READY

RANGE FLTR1

08-06-09

While the Temperature is 

still flashing, press Light

repeatedly until LOCK

appears in the LCD.

SET

RANGE

Main Screen

Main Screen

READY

RANGE FLTR1

Main Screen

READY

RANGE FLTR1

Main Screen

READY

RANGE FLTR1

Main Screen

READY

RANGE FLTR1

READY

RANGE FLTR1

Main Screen

READY

RANGE FLTR1

SET

To Set

To next item in

Main Menu

A Few

Seconds

A Few 

Seconds

A few seconds

RANGE

*****

Waiting a few 

seconds reverts 

to origianl settings

Sub-Menu Detail – Unlocking the Set Temperature or All Buttons

While pressing and holding the Temperature Button (or UP button, if available),

Slowly press and release the Light Button two times.

04-21-09

READY

RANGE FLTR1

Main Screen

A Few

Seconds

Unlocking

Indicates Flashing or Changing Segment

Key

A temperature button, used for “Action” 
Light or dedicated “Choose” button, depending on control panel configuration 

Indicates Alternating or Progressive Message - every 1/2 second

Waiting time that keeps the last change to a menu item. 

Waiting time (depends on menu item) that reverts to original setting and 

ignores any change to that menu item.

*****

This Unlock sequence may be used from any screen that may be displayed on a restricted panel. 

NOTE: If the panel has both an UP and a Down button, the ONLY button that will work in the Unlock Sequence is  
the UP button. 

The control can be restricted to prevent unwanted use or temperature adjustments.
Locking the panel prevents the controller from being used, but all automatic functions are still active. 
Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings 
cannot be adjusted. 
Temperature Lock allows access to a reduced selection of menu items.  
These include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG.

Summary of Contents for TP600

Page 1: ...ent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group TP600 and TP400 Control Panels User Interface and Programming Reference Standar...

Page 2: ...oose button depending on control panel configuration Indicates Alternating or Progressive Message every 1 2 second Waiting time that keeps the last change to a menu item Waiting time depends on menu i...

Page 3: ...As soon as the above display appears on the panel push the Jet button once to start Pump 1 in low speed and then again to switch to high speed Also push the Pump 2 or Aux button if you have a 2nd pump...

Page 4: ...temperature polling during filter cycles during freeze conditions or when another pump is on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in...

Page 5: ...be used for various reasons with a common use being a ready to use setting vs a vacation setting The Ranges are chosen using the menu structure below Each range maintains its own set temperature as p...

Page 6: ...on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Mode Menu and changing...

Page 7: ...ystem will still operate and all other user settings will be stored If filter cycles are required to run at a particular time of day resetting the clock will return the filter times to the actual prog...

Page 8: ...DY RANGE FLTR1 SET To Set To next item in Main Menu A Few Seconds A Few Seconds A few seconds RANGE Waiting a few seconds reverts to origianl settings Sub Menu Detail Unlocking the Set Temperature or...

Page 9: ...seconds Main Screen READY RANGE FLTR1 a few seconds or To next item in Main Menu SET Hold Mode M037 Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filte...

Page 10: ...aiting a few seconds reverts to original setting Wait to Revert Waiting a few seconds reverts to original setting Waiting a few seconds will lose any new Filter 1 Start Time and Run Hours and revert t...

Page 11: ...an hour SET A SET A SET A Sets 15 minute increments SET A SET SET SET Shows flashes start time to show RUN HRS to show TIMR ENDS xx xx Sets 15 minute increments A Waiting a few seconds reverts to orig...

Page 12: ...clock between 12 hr and 24 hr display RE MIN DERS Reminders Turn the reminder messages like Clean Filter On or Off CLN UP Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When...

Page 13: ...Light for CLEAN UP 05 15 09 While the Temperature is still flashing press Light repeatedly until PREF appears in the LCD SET RANGE Main Screen READY RANGE FLTR1 To next item in Main Menu UTIL To next...

Page 14: ...he bottom of the screen SSID Software ID Displays the software ID number for the System MODL System Model Displays the Model Number of the System SETP Current Setup Displays the currently selected Con...

Page 15: ...led so it may not appear This screen allows the GFCI to be tested manually from the panel and can be used to reset the automatic test feature If the GFCI Test Feature is reset the device will trip wit...

Page 16: ...ilities appears in the LCD SET RANGE Main Screen READY RANGE FLTR1 SET SET SET When set to ON Panel will display alternate readings from Senor A and Sensor B on Main Screen Back to normal operation DI...

Page 17: ...hin a few seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly Verify the funct...

Page 18: ...Sensor ATemp Sensor B Temp 24 Fault messages is the maximum Fewer messages may be displayed To FIRST item in Main Menu TEMP Range While the Temperature is still flashing press Light repeatedly until...

Page 19: ...is exited Water is too Hot OHS M029 One of the water temp sensors has detected spa water temp 110 F 43 3 C and spa functions are disabled System will auto reset when the spa water temp is below 108 F...

Page 20: ...y dr M028 Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry M0...

Page 21: ...ut of sync by 2 F or 3 F Call for Service Sensor Balance is Poor M026 The temperature sensors ARE out of sync The Sensor Balance is Poor fault has been established for at least 1 hour Call for Service...

Page 22: ...Failure System Could Not Test Trip the GFCI M036 NORTH AMERICA ONLY May indicate an unsafe installation Contact your dealer or service organization A Pump Appears to have been Stuck ON when spa was la...

Page 23: ...is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GF...

Page 24: ...od skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life Appears on a regular schedule e g every 365 days Filters should be replaced occasionally...

Page 25: ...d the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a...

Reviews: