Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Menu/Select button
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
*****
Not Available on CE Rated Systems.
A GFCI is an important safety device and is required equipment on a hot tub installation.
Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature enabled by the manufac
-
turer, the GFCI Trip Test must occur to allow proper spa function.
Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The number of days is factory programmed.) The GFCI must be reset
once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will indicate a ground fault or other unsafe condition and
the power to the spa must be shut off until a service person can correct the problem.
Forcing the GFCI Trip Test
The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu.
The GFCI should trip within a few seconds and the spa should shut down. If it does not, shut down the power and manually verify that a
GFCI breaker is installed and that the circuit and spa are wired correctly. Verify the function of the GFCI with its own test button. Restore
power to the spa and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify a successful test by
navigating to the above menu. PASS should appear after a temp button is pressed from the GFCI screen.
The end-user must be trained to expect this one-time test to occur and how to properly reset the GFCI.
Warning:
If freezing conditions exist, a GFCI should be reset immediately or spa damage could result. The end user should always be trained to test
and reset the GFCI on a regular basis.
Utilities – GFCI Test Feature
Sub-Menu Detail – Utilities - GFCI Trip
Only if GFCI
is enabled
To FIRST item in
Main Menu
(TEMP Range)
To next item in
Info Menu
(A/B°)
Only appears
if a GFCI test
has been
passed.
Press Menu/Select
repeatedly until UTIL (Utilities)
appears in the LCD.
TRIP may also
appear briefly
under certain
circumstances.
One of these screens
will appear.
If the GFCI does
NOT trip, GFCI FAIL
(see page 22)
will appear and Spa
will not operate.
The GFCI will be tripped
at a random interval.
When the GFCI trips,
the spa will shut down.
After the breaker is
reset, PASS will
appear in this menu
and the spa will
operate normally.
Main Screen
Waiting a few seconds inside the GFCI Menu will allow the screen to return to normal operation.
*****
Or wait to revert
*****
Or wait to revert
*****
Or wait to revert
U T I L
I N F O
W I L L
A R M D
- - - -
T R I P
T R I P
T R I P
R 5 E T
A R M
P A 5 5
Indicates a Menu Item that
Depends on a Manufacturer
Configuration and
may or may not appear.