INSTALLATION GUIDE   

     

42391 Rev 

A

Balboa Water Group   |   Your Single Source Solution

3

2

THANK YOU

for using Balboa Water Group spa controls.

Please visit us at

www.BalboaWaterGroup.com

TABLE OF CONTENTS

04

 WARNING 

06

 CLIM8ZONE

TM

 DIMENSIONS

08

  MINIMUM CLEARANCES

09

 COMPATIBILITY

 

MOUNTING 

10

 

CONCRETE SLAB

12

 PLATFORM

 

ELECTRICAL CONNECTIONS

14

 

NORTH AMERICA

16

 

UK, EUROPE, AUSTRALIA, NEW ZEALAND  

 

AND REST OF THE WORLD 

 PLUMBING 

20

 

SPA EQUIPMENT DIAGRAM

22

 

WATER FLOW 

26

 

PUMP UNION

28

 

CONDENSATION DRAIN

Summary of Contents for Clim8zone

Page 1: ...Installation Guide Your Single Source Solution ...

Page 2: ...sit us at www BalboaWaterGroup com TABLE OF CONTENTS 04 WARNING 06 CLIM8ZONE TM DIMENSIONS 08 MINIMUM CLEARANCES 09 COMPATIBILITY MOUNTING 10 CONCRETE SLAB 12 PLATFORM ELECTRICAL CONNECTIONS 14 NORTH AMERICA 16 UK EUROPE AUSTRALIA NEW ZEALAND AND REST OF THE WORLD PLUMBING 20 SPA EQUIPMENT DIAGRAM 22 WATER FLOW 26 PUMP UNION 28 CONDENSATION DRAIN ...

Page 3: ...ut the refrigerant odor WARNING If you power Off the CLIM8ZONE unit please empty the water in heat pump always during winter time or when the ambient temperature drops below 0 C or else the titanium heat exchanger will be damaged because of being frozen in such case your warranty will be lost WARNING WARNING Please always cut the power supply if you want to open the cabinet to reach inside the CLI...

Page 4: ...2 4 3 794 1 mm 31 3 11 1 TM INSTALLATION GUIDE 42391 Rev A Balboa Water Group Your Single Source Solution 7 6 CLIM8ZONE TM DIAGRAM DIMENSIONS 1 Enclosure Lid 2 Mounting Feet 3 Fan 4 Air Vents 5 Condensation Drain Spout 6 Lid Screws 7 Water Output 8 Water Input 9 Control Data Bus 10 Power Line Box 11 Bonding Lugs North America Figure 1 Figure 2 ...

Page 5: ...P CONTROL SYSTEMS The CLIM8ZONE TM unit is compatible with BP Control Systems that have one of the following agency prefixes BP20 BP21 BP501 BP6 BP2 BP1 The agency prefix is noted on the control system identification label Updated BP Control System software and control panel software is required for CLIM8ZONE TM Follow the minimum clearance requirements shown below during installation and operatio...

Page 6: ...he mounting holes figure 4 G and the cement slab removing all dust and debris If necessary used compressed air to clean the mounting holes 5 Move the CLIM8ZONETM unit back into its final position making sure the mounting holes in the cement slab align with the corresponding mounting holes in the feet 6 Place a foot pad figure 4 C under each foot 7 Install the washer figure 4 B expansion wedge anch...

Page 7: ...e marks from step 1 as a guide drill one mounting hole for each foot into the platform figure 5 B 3 Clean the mounting holes and the platform figure 5 C removing all dust and debris 4 Move the CLIM8ZONETM unit back to its final position making sure the mounting holes in the platform align with the corresponding mounting holes in the feet 5 Place a rubber foot pad under each foot figure 4 C Rubber ...

Page 8: ...ng lug figure 6 G and must be electrically bonded to the spa common bonding grid Connect the grounding lug with the spa common bonding grid with a 8 minimum solid copper wire 7 Power On the BP Control System at the GFCI or circuit breaker WARNING There are no user serviceable parts inside of the CLIM8ZONETM unit or the control system All connections must be made by a qualified electrician in accor...

Page 9: ... figure 7 E to the circuit board of the BP Control System figure 7 B Refer to the wiring diagram for the proper connection The connectors are keyed so make sure they are properly aligned figure 7 F before making the connection 5 Reinstall the lid of the BP Control System figure 7 B 6 Power On the BP Control System at the RCD or circuit breaker WARNING There are no user serviceable parts inside of ...

Page 10: ...tion The connectors are keyed so make sure they are properly aligned figure 7 F before making the connection 5 Reinstall the lid of the BP Control System figure 8 B 6 Power On the BP Control System at the RCD or circuit breaker WARNING There are no user serviceable parts inside of the CLIM8ZONETM unit or the control system All connections must be made by a qualified electrician in accordance with ...

Page 11: ...ion Spout J Water Inlet Main Power P Slice Valve SPA EQUIPMENT DIAGRAM EQUIPMENT CONTAINED IN THE SPA ENCLOSURE A CLIM8ZONE TM Unit I Condensation Spout B Water Outlet J Water Inlet C Slice Valve K Slice Valve D Slice Valve optional L Flow Control Valve or Ball Valve E Slice Valve optional M Control Panel F Ozone UV N BP Control System G Spa Water O Main Power H Heating Pump P Slice Valve SPA EQUI...

Page 12: ...ZONETM unit will shut off all heating or cooling for safety reasons anytime the water temperature exceeds 43 C 109 4 F for 5 seconds at the outlet or inlet Ozone UV Make sure any ozone UV units are installed down stream from the CLIM8ZONETM unit Figure 9 F CLIM8ZONE TM Water Flow Rates US Gallons Per Minute Liter Per Minute Meter3 Hour Optimal flow rate for heating cooling 11 89 45 0 2 70 Maximum ...

Page 13: ...ing pumps 1 Circulation pump 2 Two speed pump If the spa has a two speed heating pump it will circulate water at low speed through the electric heater HEAT PUMP A heat pump can both heat or cool spa water and all of the heating and cooling equipment is contained in the heat pump CLIM8ZONE figure 11 A is a heat pump Water Flow Direction Spa Water A I K B J C L O F G E D H M N A CLIM8ZONE Unit B Wat...

Page 14: ...nted properly on Pump Union 1 figure 10 B Install Pump Union 1 into the water outlet as shown here 3 Tighten Pump Union 1 with the wrench figure 12 G as shown here Wear gloves to protect your hands from the edges of the wrench Before beginning step 4 make sure Gasket 2 figure 12 F is still properly seated as shown here Water Inlet C Water Outlet B 4 Install Pump Union 2 figure 12 C onto the end of...

Page 15: ...t Hose Clamp 2 Tighten the hose clamp with a Philips head screw driver to secure the hose in place and create a water tight fit As much as 3 liters of condensation per hour may flow from the end of the hose Make sure the end of the hose has proper drainage so water does not collect around the CLIM8ZONETM unit Condensation is normal and is not a water leak Condensation Hose NOTES TM INSTALLATION GU...

Page 16: ...omer Service is available M F 7 00AM to 6 00PM PT Corporate Office Balboa Water Group 3030 Airway Avenue Costa Mesa CA 92626 MEXICO OPERATIONS Balboa Water Group Aguila Azteca 6011 Baja Maq El Aquila Mexico 22221 EUROPEAN OPERATIONS Balboa Water Group Hydroair International ApS Roustvej 50 DK 6800 Varde ...