ELECTRICAL
CONNECTIONS
3 SERVICE
UK, EUROPE, AUSTRALIA, NEW ZEALAND AND REST OF THE WORLD
Follow these steps to make the
electrical connections:
1 - Make sure the BP Control System (figure 8, B) is
powered Off at the RCD or circuit breaker before starting
the installation process.
2 - Remove the lid from the BP Control System
(figure 8, B) by loosening these two screws (figure 8, C)
with a Phillips head screwdriver.
There is a wiring diagram in the inside surface of the lid.
Refer to the wiring diagram during steps 3 and 4.
3 - Connect the power cable (figure 8, D) to the adaptor
(figure 8, F). Connect the adaptor to the circuit board of
the BP Control System (figure 8, B). Refer to the wiring
diagram for the proper connection. The connectors are
keyed, so make sure they are properly aligned
(figure 8, F) before making the connections.
4 - Connect the data bus (figure 8, E) to the circuit board
of the BP Control System (figure 8, B). Refer to the wiring
diagram for the proper connection. The connectors are
keyed, so make sure they are properly aligned
(figure 7, F) before making the connection.
5 - Reinstall the lid of the BP Control System
(figure 8, B).
6 - Power On the BP Control System at the RCD or
circuit breaker.
WARNING
There are no user serviceable parts inside of
the CLIM8ZONE
TM
unit or the control system. All
connections must be made by a qualified electrician in
accordance with the country or local electrical codes in
effect at the time of installation.
IMPORTANT
◆
Earthing is required for protection against
short-circuits inside the unit. Always provide a good
earth connection.
◆
Before connecting the unit, verify that the supply
voltage matches the required voltage of the heat pump.
◆
It is recommended to connect the heat pump to a
circuit with its own fuse or circuit breaker.
CLIM8ZONE
TM
MAXIMUM CURRENT:
220-240 VAC
50-60 Hz
5.71 A
F
Data Bus
E
BP Control System
B
CLIM8ZONE
TM
Unit
A
C
Power cable adaptor
for a 3 service input
F
Adaptor
D
CLIM8ZONE
TM
Power Cable
Connect to
BP Control System (B)
Connect to CLIM8ZONE
power cable (D1)
TM
INSTALLATION GUIDE
42391 Rev
A
Balboa Water Group | Your Single Source Solution
19
18
Figure 8