- 4 -
Filtration
The system is factory-programmed with one filter cycle that will run in the evening (assuming the time-of-
day is properly set) when energy rates are
often lower. The filter time and duration are programmable. Refer to the TP600 User Guide (40940) for
detailed instructions.
A second filter cycle can be enabled as needed.
Dual Temperature Ranges
This system incorporates two temperature range settings with independent set temperatures. The
High
Range
is indicated in the display
and might be set between 80
°
F and 104
°
F. The
Low Range
is
indicated in the display
and might be set between 50
°
F and 99
°
F. Low Range may be
economical during non-use periods. More specific temperature ranges, such as 50
°
F to 79
°
F for low
range, or 90
°
F to 104
°
F for High Range, may determined by the manufacturer.
Ready and Rest Modes
If the filtration pump is a 2-Speed Pump 1,
Mode will circulate water every 1/2 hour, using Pump 1
Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display.
This is known as
“
polling.
”
Mode will only allow heating during programmed filter cycles. Since
polling does not occur, the temperature display may not show a current temperature until the filtration pump
has been running for a minute or two.
Mode may appear when Jets 1 is activated.
Complete Reference
Download the complete User Interface and Programming Guide at
instruments.com/zz40940_download.zip
User Interface and Programming Reference – Standard Menus
System Model: BP-Series Systems are BP5XX, BP6XX, BP1XXX, BP2XXX.
Software Version: 7.0 and later
Panel Model: TP600 Series TP400 Series
Software Version: 2.3 or later 2.4 or later
1. First Start-up
Navigating the entire menu structure is done with 2 or 3 buttons on the control panel.Some panels have separate
WARM (Up) and COOL (Down) buttons, while others have a single Temperature button. In the navigation
diagramsTemperature buttons are indicated by a single button icon.
Panels that have two Temperature buttons (Warm and Cool) can use both of them to simplify navigation and
programming where a single Temperature icon is shown.The LIGHT Button is also used to choose the various
menus and navigate each section.Typical use of the Temperature button(s) allows changing the Set
Temperature while the numbers are flashing in the LCD.Pressing the LIGHT button while the numbers are
flashing will enter the menus.The menus can be exited with certain button presses. Simply waiting for several
seconds will return the panel operation to normal.
Power-up Screens
Each time the System powers up,
a series of numbers is displayed.
****
Main Screen
While the Temperature is
still flashing, press Light.